A fast and simple approach for the estimation of a radiological source from localised measurements after the explosion of a radiological dispersal device.
نویسندگان
چکیده
After an explosion of a radiological dispersal device, decision-makers need to implement countermeasures as soon as possible to minimise the radiation-induced risks to the population. In this work, the authors present a tool, which can help providing information about the approximate size of source term and radioactive contamination based on a Gaussian Plume model with the use of available measurements for liquid or aerosolised radioactivity. For two-field tests, the source term and spatial distribution of deposited radioactivity are estimated. A sensitivity analysis of the dependence on deposition velocity is carried out. In case of weak winds, a diffusive process along the wind direction is retained in the model.
منابع مشابه
ارزیابی نتایج طولانی مدت دکورتیکاسیون لاپاراسکوپیک کیستهای علامتدار کلیه
Background & Aims: Renal cysts are common disorders in adults. Traditionally, symptomatic patients with renal cysts are treated with percutaneous aspiration with or without using sclerosing agent. However, the recurrence rate is high in this procedure. Thus, we assessed the long-term outcomes of laparoscopic decortication of simple renal cysts from the clinical and radiologic points of view...
متن کاملQuantification of radionuclides and associated radiological risk estimation of coal combustion residues from a South African coal-fired power plant
Background: Radionuclides occur in coal combustion residues, such as fly ash and bottom ash, which are by-products of coal combustion. They pose potential radiological risks to people present in the surrounding areas. Materials and Methods: Gamma spectrometry was performed to determine the radionuclide activity concentrations in a coal-driven power plant located in the Limpopo province, South A...
متن کاملOptimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD)
Background Increasing the x-ray film to focus distance (FFD), has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. In the previous study, we demonstrated a 32% reduction in absorbed dose is achievable due to increasing the FFD from 100 to 130 cm during pediatric chest radiography. The aim of this study was to examine whether in...
متن کاملTreatment of neglected mal:union: of the distal radius: a cases series study
Background: Mal:::union::: is the most common complication following distal radius fractures. Aim of this study was to evaluate the results of distal radius corrective osteotomy and plate fixation by dorsal approach in the mal:::union:::. Methods: In this retrospective study, 14 patients with neglected distal radius mal:::union::: from 2005 to 2011 were studied. All patients were treated ...
متن کاملA Novel Suture Button Construct for Acute Ankle Syndesmotic Injuries; A Prospective Clinical and Radiological Analysis.
Background: The importance of the syndesmosis in ankle stability is well recognized. Numerous means of fixation have been described for syndesmotic injuries including the suture button technique. Significant cost limits the use the commercially available options. We, therefore, designed a cheap and readily available alternative construct. We aim to assess the results of using a novel suture-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiation protection dosimetry
دوره 158 4 شماره
صفحات -
تاریخ انتشار 2014