Conjugate heat transfer problem of a disc winding in a power transformer is studied using commercial CFD software. The study is done for oil flow, temperature distribution, hot spot location and temperature of the winding, for three different cases: first, no oil leakage past the top washer; second, partial leakage due to a 2 mm gap between the top oil guiding washer and cylindrical pressboard; third, full leakage, i.e., no oil guiding washer. The effect of leakage is studied for both uniform and non-uniform heat loss distributions in the winding. The leakage is found to lead to an onset of a reversal in flow direction: in the horizontal channels of the last pass of the winding. Under the effect of leakage, the variation in thermal performance of the winding is substantial for uniform and negligible for more practically encountered non-uniform heat loss distribution. However, for non-uniform heat loss distribution, the leakage leads to two local hotpots as compared to one for the non-leakage case. The partial as compared to complete leakage is found to give almost same thermal performance. This study will be useful – for transformer manufacturers – to realize the importance of leakage free washer design of a disc-type transformer winding. © 2015 Elsevier Ltd. All rights reserved.
منابع مشابه
An Investigation on Stability, Electrical and Thermal Characteristics of Transformer Insulting Oil Nanofluids
Transformer insulating oil nanofluid is made to improve dielectric and thermal properties of the oil by employing nanoparticles with proper properties. In the current work, nanofluids based on transformer mineral oil were prepared by three procedures using diamond nanoparticles with high thermal conductivity, as well as high dielectric properties. It was tried to consider the impacts of surfact...
متن کاملCharacterization of Power Transformer Electromagnetic Forces Affected by Winding Faults
Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...
متن کاملEfficiency Improvement of the Flyback Converter Based on High Frequency Transformer Winding Rearrangement
In this paper, a novel method for loss reduction and efficiency optimization of the high frequency flyback transformers is proposed based on rearrangement of the windings. According to detailed analysis of the high frequency flyback transformer using FEM technique, a novel and simple approach for its design improvement and loss reduction is introduced. It is shown that leakage flux scattering i...
متن کاملمدلسازی حالت گذرای حرارتی در ترانسفورماتور چند سیمپیچه دوطبقه مبتنی بر روش تفاضلات محدود و شبکههای عصبی مصنوعی
Nowadays, multi-winding transformers are widely used in traction systems and steel manufacturer. Multi-winding transformer that is used in these systems has especial geometry (that is usually called as split-winding transformer) and encounters with serious magnetic and thermal difficulties. According to the special geometry of split-winding transformer, studding the transient thermal behavior ...
متن کاملElectrical and Thermal investigation of Transformer Oil base Nanofluids
Transformer oil is one of the most important materials which are used in electrical and transformer industrial. The main function is protection and insulation of transformer core components, as well as heat transfer from its core to environment. Improving the performance of this material has been one of the researchers' concerns. The effect of different nanoparticle on the electrical breakdown ...