A Student-Designed Potentiometric Titration: Quantitative Determination of Iron(II) by Caro's Acid Titration

نویسندگان

  • Joyce R. Powell
  • Sheryl A. Tucker
  • William E. Acree
چکیده

Oxidation–reduction titrations and potentiometric methods provide a convenient experimental means to quantitatively determine compositions of unknown mixtures containing oxidizable/reducible species. Over the past decade, numerous titration methods have appeared in this Journal (1–6) and in standard laboratory manuals (7–10) involving common titrants such as potassium dichromate, iodine, potassium permanganate, cerium(IV) sulfate, and sodium thiosulfate. As representative examples, Kaufman and DeVoe (3) devised a simplified redox method for total iron content by first reducing any iron(III) to iron(II) with metallic zinc, followed by potassium dichromate titration using sodium diphenylamine sulfonate as the indicator. Klett et al. (4) proposed a similar Fe(II)–Cr(VI) titration method, except that titanium(II) chloride was used to reduce all iron to the 2+ oxidation state. Both methods generate waste solutions containing chromium, which should be disposed of by an environmentally safe method (11, 12). Chromium(III) is considered a “high hazard” ion, and may induce toxic effects. Similarly, chromium(VI) is very toxic and is also a suspected carcinogen (11, 12). Harris and Kratochvil (7) described the permanganimetric oxidation of iron and the iodometric determination of copper in brass. Pickering and Monts (6) described a rather novel laboratory experiment involving titration of the nonstoichiometric WO2.223.0 blue oxide, “mineral blue”, with potassium permanganate. This latter method requires that the titration solution be heated, and chloride ions are known to interfere in potassium permanganate titrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Coated Graphite Potentiometric Sensor for Selective Determination of Copper (II) Ions

A highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 m...

متن کامل

The determination of iron in organic substances: Micro-colorimetry as ferric thiocyanate. II. Potentiometric titration with titanous sulphate.

IN certain experiments on iron metabolism, involving the iron-containing protein of egg-yolk, lecitho-vitellin, we planned to make a large number of iron estimations. To conserve our small supply of protein, the preparation of which had involved considerable time and labour, we desired to cut down the size of the sample analysed to the smallest amount on which an accurate iron determination cou...

متن کامل

Determination of Magnesium (II) by a Coated Graphite Electrode Based on Risperidone as an Ionophore

In this research, a coated graphite electrode was constructed for determination of Mg2+ in pharmaceutical supplements. The designed sensor demonstrates an ideal Nernstian slope (30.1 mV. Decade-1) over a wide concentration range (1×10-6- 1×10-1 Mol L-1). The selectivity of the sensor was evaluated over 16 different cations by matched potential method and no serious interference was observed fro...

متن کامل

ESTIMATION OF POTENTIAL AND EFFECTIVE BR?NSTED ACID SITE CONCENTRATIONS IN ACIDIC MORDENITES BY CONDUCTOMETRIC TITRATION METHOD

Quantitative determination of Br?nsted acid sites in acidic mordenite samples with varying proton concentrations has been studied using aqueous conductometric titration method. Conductometric titration of the ammonium form of mordenite with sodium hydroxide is feasible and the results indicate potential number of Br?nsted acid sites. However, Br?nsted acid sites concentration in acidic mordenit...

متن کامل

Polymeric Membrane Sensor for Potentiometric Determination of Tin(II) Ions

Tin(II)-ion-selective electrode consisting of dibenzo-18-crown-6 (DB18C6) as an ionophore inPVC matrix was developed. The influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. The electrodeshowed a near Nernstian response for Sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997