In vivo assessment of optimal b-value range for perfusion-insensitive apparent diffusion coefficient imaging.

نویسندگان

  • Moti Freiman
  • Stephan D Voss
  • Robert V Mulkern
  • Jeannette M Perez-Rossello
  • Michael J Callahan
  • Simon K Warfield
چکیده

PURPOSE To assess the optimal b-values range for perfusion-insensitive apparent diffusion coefficient (ADC) imaging of abdominal organs using short-duration DW-MRI acquisitions with currently available ADC estimation methods. METHODS DW-MRI data of 15 subjects were acquired with eight b-values in the range of 5-800 s∕mm(2). The reference-standard, a perfusion insensitive, ADC value (ADC(IVIM)), was computed using an intravoxel incoherent motion (IVIM) model with all acquired diffusion-weighted images. Simulated DW-MRI data was generated using an IVIM model with b-values in the range of 0-1200 s∕mm(2). Monoexponential ADC estimates were calculated using: (1) Two-point estimator (ADC(2)); (2) least squares three-point (ADC(3)) estimator and; (3) Rician noise model estimator (ADC(R)). The authors found the optimal b-values for perfusion-insensitive ADC calculations by minimizing the relative root mean square error (RRMS) between the ADC(IVIM) and the monoexponential ADC values for each estimation method and organ. RESULTS Low b-value = 300 s∕mm(2) and high b-value = 1200 s∕mm(2) minimized the RRMS between the estimated ADC and the reference-standard ADC(IVIM) to less than 5% using the ADC(3) estimator. By considering only the in vivo DW-MRI data, the combination of low b-value = 270 s∕mm(2) and high b-value of 800 s∕mm(2) minimized the RRMS between the estimated ADC and the reference-standard ADC(IVIM) to <7% using the ADC(3) estimator. For all estimators, the RRMS between the estimated ADC and the reference standard ADC correlated strongly with the perfusion-fraction parameter of the IVIM model (r = [0.78-0.83], p ≤ 0.003). CONCLUSIONS The perfusion compartment in DW-MRI signal decay correlates strongly with the RRMS in ADC estimates from short-duration DW-MRI. The impact of the perfusion compartment on ADC estimations depends, however, on the choice of b-values and estimation method utilized. Likewise, perfusion-related errors can be reduced to <7% by carefully selecting the b-values used for ADC calculations and method of estimation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of Apparent diffusion coefficient value in Diffusion Weighted imaging of MRI to assessment of radiotherapy efficiency in the patient with glioma tumor during treatment

Introduction: Glioma is the most common primary malignancy of cerebral neoplasms in adults, which in spite of therapeutic significant efforts, has a very poor prognosis. The current standard treatment of these patients generally includes surgery and radiotherapy or concurrent chemoradiotherapy with 6 courses of adjuvant use of temozolomide tabs. During these years, the nervous...

متن کامل

Assessment of Cervical Cancer with a Parameter-Free Intravoxel Incoherent Motion Imaging Algorithm

OBJECTIVE To evaluate the feasibility of a parameter-free intravoxel incoherent motion (IVIM) approach in cervical cancer, to assess the optimal b-value threshold, and to preliminarily examine differences in the derived perfusion and diffusion parameters for different histological cancer types. MATERIALS AND METHODS After Institutional Review Board approval, 19 female patients (mean age, 54 y...

متن کامل

Assessment of diagnostic value of DWI technique in the evaluation of liver fibrosis

Introduction: The liver fibrosis is caused by extracellular accumulation of cluster, glycos amino glycans and proteoglycans, which this extracellular accumulation may limit the penetration and molecular movement of water in the tissue, so the Diffusion weighted imaging(DWI) technique is due to the sensitivity to the movement and release of water molecules Can show this restrict...

متن کامل

Improved in-vivo cardiac DTI using optimal b-values

Background There has been much recent interest in the microstructural information available using cardiac diffusion tensor imaging (cDTI)[1-3]. cDTI measures signal loss between a reference (b0) and a diffusion weighted image. The signal loss is caused by both diffusion and other sources of intravoxel incoherent motion, such as microvascular perfusion. By applying diffusion weighting to the ref...

متن کامل

Differentiation of benign and malignant breast lesions by apparent diffusion coefficient value in mass and non-mass lesions

Background: Diffusion-weighted imaging (DWI) is one of methods in evaluation of breast lesions. We aimed to investigate the apparent diffusion coefficient (ADC) values in breast tumors and their accuracy in differentiating benign versus malignant lesions. Methods: In this cross-sectional study, 72 patients with 88 breast lesions were investigated by 1.5-T breast MRI from 2015 to 2017 in Athari...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 8  شماره 

صفحات  -

تاریخ انتشار 2012