Comparison of triple-dose single-donor platelet collection by the AmicusTM and the Trima Accel® blood-cell separators

ثبت نشده
چکیده

Objective: The purpose of this study was to compare triple-dose single-donor platelet collection using AmicusTM and Trima Accel® blood-cell separators. Method: The same 25 donors underwent triple-dose single-donor platelet collection using the Amicus™ and Trima Accel® systems. The target endpoint was > 9.5 × 1011 platelets. Processing time, apheresis characteristics, donor safety, and satisfaction, were evaluated. In all, 18 donors completed the study; all of the resulting 36 donations were evaluated. Results: The collection ef ciency of both systems were not statistically different (80.25±10.64 vs. 76.63±6.06 %, p=0.228), the amount of whole blood volume processed was high (5274.50±874.86 vs. 4428.28±593.09 ml, p <0.001), and it used more infused ACD-A (593.56 ±92.74 vs. 521.17± 72.02 ml, p=0.010). The Trima Accel® process was faster (101.10±16.58 vs. 88.61±16.71 min, p=0.002). Most donors expressed satisfaction. The Trima Accel® system scored higher because its comparative speed (9.17 vs.9.22, p=0.805). After separation into blood constituents, all products had < 5.0 x106 (1.04±3.3 vs. 0.44 ±1.05 x 106/unit, p=0.372) residual white blood cells. No severe adverse reactions were noted with either of the instruments. Conclusion: Our experimental data showed that triple-dose platelet collection was safe using either system. The platelet yields satis ed American Association of Blood Banks (AABB) guidelines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Prospective Crossover Trial Comparing Performance and in vitro Platelet Quality of Three New Apheresis Devices with Current Equipment

Background: To improve productivity of automated platelet (PLT) collection, the industry has introduced new instruments or modifications to existing equipment. Materials and Methods: Data obtained from 8 regular PLT apheresis donors randomized to double(DDC) or triple-dose PLT collection (TDC) with the BAXTER Amicus (AM), the HAEMONETICS MCS Plus (MCS+), and the GAMBRO Trima Accel (TA) were eva...

متن کامل

Thrombingeneration vor und nach Multikomponentenspende

IThe development of apheresis technology has increased efficiency in donor blood use by collecting specific blood components in several combinations. The question of donor safety raised by the contact of donor blood with foreign, only in part biocompatible surfaces remains. The aim of this study was to estimate the effect of multicomponent blood collection on thrombin generation performing an o...

متن کامل

The quality of platelet concentrates produced by COBE Spectra and Trima Accel during storage for 7 days as assessed by in vitro methods

BACKGROUND: The quality of PLT concentrates (PCs) can be evaluated using various in vitro methods. A new technique, free oscillation rheometry (FOR), can be used to monitor coagulation properties of PCs and gives information on clotting time and coagulum elasticity. This study compared the quality of apheresis PCs produced by COBE Spectra and Trima Accel during storage for 7 days using in vitro...

متن کامل

Red cell apheresis with automated in-line filtration.

BACKGROUND The aim of this study was to provide data on concurrent red blood cell (RBC) and platelet (PLT) apheresis with RBC in-line leukoreduction and automated addition of saline-adenine-glucose-mannitol (SAGM) using the new version (V6.0) of Trima Accel®. METHODS In this two-center paired study, each subject completed a test and a control procedure with an interval of 9 weeks between proc...

متن کامل

Recovery of white blood cells and platelets from leukoreduction system chambers of Trima Accel and COBE Spectra plateletpheresis devices.

Recently, Dietz and coworkers described a new source of viable peripheral blood mononuclear cells (PBMNCs) that they recovered from leukoreduction system chambers (LRSCs) of Trima Accel apheresis devices (Gambro BCT, Lakewood, CO) after routine donor plateletpheresis procedures. These white blood cells (WBCs), which are usually discarded, functioned excellently in conventional in vitro assays a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016