Chemiluminescence immunoassay of aldosterone in serum.

نویسندگان

  • T V Stabler
  • A L Siegel
چکیده

A chemiluminescence immunoassay (CLI) for the direct measurement of aldosterone in serum was developed with aminobutylethyl isoluminol (ABEI) as the label. In this competitive assay the samples are incubated with sample, antibody, aldosterone-carboxymethyl oxime-ABEI, and paramagnetic particles coated with second antibody. After magnetic separation and washing, the samples are incubated with 200 microL of NaOH (2 mol/L) at 60 degrees C for 30 min. In the luminometer the chemiluminescence is produced by the serial injection of 150 microL each of microperoxidase and H2O2 solutions. Comparison of results with an RIA method showed excellent agreement: CLI = 1.001 RIA + 0.020 (r = 0.99, n = 93). The method is simple and avoids the hazards and costs associated with isotopic waste. The label has a shelf life of at least two years.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stabilization of glucose in blood specimens: mechanism of delay in fluoride inhibition of glycolysis.

1. Wion-Barbot N, Schuffenecker I, Niccoli P, Conte-Devolx B, Lecomte P, Houdent C, et al. Results of the calcitonin stimulation test in normal volunteers compared with genetically unaffected members of MEN 2A and familial medullary thyroid carcinoma families. Ann Endocrinol (Paris) 1997;58:302–8. 2. Motte P, Vauzelle P, Gardet P, Ghillani P, Caillou B, Parmentier C, et al. Construction and cli...

متن کامل

Effect of ATP-Dependent K+ Channel Openers and Blockers on Serum Concentration of Aldosterone in Rats

There are many reports for involvement of ATP-sensitive potassium channels in pancreatic, cardiac and vascular smooth muscle cells. This study examined the effect of single doses of K+ channel openers diazoxide, minoxidil and K+ channel blockers chlorpropamide, glibenclamide on serum concentration of aldosterone in male rats. Blood samples were obtained 60 minutes after drug treatment and serum...

متن کامل

Solid-phase chemiluminescence immunoassay for progesterone in unextracted serum.

We describe a simple, solid-phase chemiluminescence immunoassay for progesterone in 10 microL of unextracted serum ("direct" assay). Danazol at pH 8.0 is included (100 ng per tube) to displace progesterone from binding proteins in serum. A progesterone-11 alpha-hemisuccinyl-aminobutylethyl isoluminol conjugate serves as the chemiluminescent ligand marker and homologous antiprogesterone IgG cova...

متن کامل

Protein-enhanced fluorescein chemiluminescence used in an immunoassay for rubella antibody in serum.

The chemiluminescence of fluorescein derivatives is greatly enhanced when they are conjugated to proteins. We exploited this property in devising a chemiluminescence immunoassay for rubella antibodies. In this sequential "sandwich"-type assay, tubes coated with rubella antigen are used for antibody separation and goat antibody to human IgG conjugated with fluorescein isothiocyanate is used for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 37 11  شماره 

صفحات  -

تاریخ انتشار 1991