Review Draft An Evaluation of Hospital Radiation Detectors for Use in Screening Potentially Contaminated Individuals

نویسنده

  • R. H. Olsher
چکیده

The detonation of an improvised nuclear device or a radioactive dispersal device (RDD) would lead to widespread radioactive contamination, including the potential contamination of individuals. If such an event were to happen, it would be desirable to have various means of rapidly scanning individuals to determine if they have either external or internal contamination and to be able to determine when decontamination procedures have been successful. Nearly all hospitals provide nuclear medicine services for their patients. Therefore, most hospitals already possess various pieces of radiation detection equipment, including gamma cameras, thyroid uptake counters, Geiger-Mueller counters, and other portable radiation detection and measurement instruments. In addition, because of concerns over radioactivity inadvertently leaving the hospital in normal trash or over receiving patients in the emergency department who might be unknowingly contaminated with radioactive materials, a number of hospital have installed portal monitors that are capable of detecting low levels of radioactivity. SC&A, Inc., in collaboration with the Hershey Medical Center (HMC), performed studies to determine the suitability of radiation detection and imaging systems commonly found in hospitals for rapidly scanning individuals for internal contamination. The present chapter describes field studies to evaluate the potential use of nuclear medicine gamma camera systems, thyroid uptake counters, and portal monitors for detecting and measuring low levels of internal contamination. Chapter 2 describes the use of computer models to simulate the response of two models of gamma cameras to radionuclides distributed in the lungs of an anthropomorphic phantom based on Reference Man. Various phantoms were potentially available for this study, including a Rando Phantom, 1 and a chest and torso phantom 2 used in the nuclear power industry for whole body counting (see Figure 1-1). However, these phantoms could not be loaded with the readily available sources used for these measurements without permanently altering the phantom, such as by drilling larger holes, which made them unsuitable for use in the present study. To obviate these difficulties, a simplified phantom was constructed from slabs of poly(methyl methacrylate) (PMMA), a clear plastic commonly known as acrylic and sold under various brand names, including Plexiglas®, Lucite®, and Acrylite®. PMMA has the empirical chemical formula (C O H) and a typical density of 1.19 g/cm. 3 5 2 8 n Prior to adopting the acrylic phantom, its radiation absorption properties were compared to equal thicknesses of the Rando Phantom. When the results showed that the two materials produced the …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

Evaluation of the role of system matrix in SPECT images reconstructed by OSEM technique

  Introduction: Ordered subset expectation maximization (OSEM), is an effective iterative method for SPECT image reconstruction. The aim of this study is the evaluation of the role of system matrix in OSEM image reconstruction method using four different physical beam radiation models with three detection configurations. Methods: SPECT was done with an arc of 180 deg...

متن کامل

First Trimester Potential Biochemical Predictive Tests for Gestational Diabetes Mellitus: A Systematic Review

Objective: Gestational diabetes mellitus (GDM) is the most common metabolic complication during pregnancy. So, a large number of studies have evaluated the usefulness of different screening tests. The aim of this study was focused on the potential of only first-trimester screening used in the prediction of GDM. Materials and Methods: In this systematic review, we searched PubMed, EMBASE, and S...

متن کامل

Imaging of accidental contamination with F-18-solution; a quick trouble-shooting procedure

 To the best of our knowledge, imaging of accidental exposure to radioactive fluorine-18 (F-18) due to liquid spill has not been described earlier in the scientific literature. The short half-life of F-18 (t½=110 min), current radiation safety requirements, and Good Manufacturing Practice (GMP) regulations on radiopharmaceuticals have restrained the occurrence of these incidents. The possibilit...

متن کامل

Defining evaluation criteria for Health Information Systems using Human, organization and technology-fit factors (HOT-fit): systematic review

Introduction: The purpose of this study is to conduct a review of a series of published studies on evaluation of health information systems in order to determine the criteria of evaluation of hospital information systems using HOT-fit framework Information sources or data: The present study is a review study to evaluate articles of English databases PubMed, scupos and Persian databases Irandoc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005