Novel assessment of temporal variation in fractionated electrograms using histogram analysis of local fractionation interval in patients with persistent atrial fibrillation.

نویسندگان

  • Yenn-Jiang Lin
  • Kazuyoshi Suenari
  • Men-Tzung Lo
  • Chen Lin
  • Wan-Hsin Hsieh
  • Shih-Lin Chang
  • Li-Wei Lo
  • Yu-Feng Hu
  • Chen-Chuan Cheng
  • Yasuki Kihara
  • Tze-Fan Chao
  • Beny Hartono
  • Tsu-Juey Wu
  • Wei-Shiang Lin
  • Ke-Hsin Hsu
  • Ambrose S Kibos
  • Norden E Huang
  • Shih-Ann Chen
چکیده

BACKGROUND The characteristics of atrial electrograms associated with atrial fibrillation (AF) termination are controversial. We investigated the electrogram characteristics that indicate procedural AF termination during continuous complex fractionated electrogram ablation. METHODS AND RESULTS Fifty-two consecutive patients with persistent AF (47 men; aged 54 ± 9 years), who underwent electrogram-based catheter ablation in the left atrium and coronary sinus after pulmonary vein isolation, were enrolled. The intracardiac bipolar atrial electrogram recordings were characterized by (1) fractionation interval (FI) analysis (>6 seconds), (2) kurtosis (shape of the FI histogram), and (3) skewness (asymmetry of the FI histogram). Sites showing complex, fractionated electrograms (mean FI ≤ 60 ms) were targeted, and AF was terminated in 20 patients (38%) after the pulmonary vein isolation. The conventional complex fractionated electrogram sites (mean ≤ 120 ms) in patients with AF termination exhibited higher median kurtosis (2.69 [interquartile range, 2.03-3.46] versus 2.35 [interquartile range, 1.79-2.48]; P=0.024) and higher complex fractionated electrogram-mean interval (102.7 ± 19.8 versus 87.7 ± 15.0; P=0.008) than patients without AF termination. Furthermore, AF termination sites had higher median kurtosis than targeted sites without AF termination (5.13 [interquartile range, 3.51-6.47] versus 4.18 [interquartile range, 2.91-5.34]; P<0.01) in patients with procedural termination. In addition, patients with AF termination had a higher sinus rhythm maintenance rate after a single procedure than patients without AF termination (log-rank test, P=0.007). CONCLUSIONS A kurtosis analysis using the FI histogram may be a useful tool in identifying the critical substrate for persistent AF and potential responders to catheter ablation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Relationship Between Spatiotemporal Variation of Tissue Excitation and Electrode Spatial Resolution

Background—Fractionated electrograms are used by some as targets for ablation in atrial and ventricular arrhythmias. Fractionation has been demonstrated to result when there is repetitive or asynchronous activation of separate groups of cells within the recording region of a mapping electrode(s). Methods and Results—Using a computer model, we generated tissue activation patterns with increasing...

متن کامل

Electrogram fractionation: the relationship between spatiotemporal variation of tissue excitation and electrode spatial resolution.

BACKGROUND Fractionated electrograms are used by some as targets for ablation in atrial and ventricular arrhythmias. Fractionation has been demonstrated to result when there is repetitive or asynchronous activation of separate groups of cells within the recording region of a mapping electrode(s). METHODS AND RESULTS Using a computer model, we generated tissue activation patterns with increasi...

متن کامل

Atrial Electrogram Fractionation Distribution before and after Pulmonary Vein Isolation in Human Persistent Atrial Fibrillation—A Retrospective Multivariate Statistical Analysis

Purpose: Complex fractionated atrial electrograms (CFAE)-guided ablation after pulmonary vein isolation (PVI) has been used for persistent atrial fibrillation (persAF) therapy. This strategy has shown suboptimal outcomes due to, among other factors, undetected changes in the atrial tissue following PVI. In the present work, we investigate CFAE distribution before and after PVI in patients with ...

متن کامل

The Spatio-temporal Behavior of Atrial Electrogram Fractionation in Persistent Atrial Fibrillation

The temporal behavior of atrial electrograms (AEGs) during persistent atrial fibrillation (persAF) remains poorly understood. In the present work, we investigated the temporal behavior of consecutive AEGs and the consistency of complex fractionated atrial electrograms (CFAEs) with the CARTO (Biosense Webster) criterion. 797 bipolar AEGs were exported from NavX (St. Jude Medical) with three segm...

متن کامل

Robust Classification of Endocardial Electrograms Fractionation in Human using Nearest Mean Classifier

Complex fractionated atrial electrograms (CFAEs) may represent the electrophysiological substrate for atrial fibrillation (AF). Progress in signal processing algorithms to identify CFAEs sites is crucial for the development of AF ablation strategies. A novel algorithm for automated description of atrial electrograms (A-EGMs) fractionation based on wavelet transform and several statistical patte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 5 5  شماره 

صفحات  -

تاریخ انتشار 2012