Cardiac Transplantation and Surgery for Heart Failure Biventricular Circulatory Support With Two Miniaturized Implantable Assist Devices

نویسندگان

  • Thomas Krabatsch
  • Martin Schweiger
چکیده

Background—Up to 30% of patients with end-stage heart failure experience biventricular failure that requires biventricular mechanical support. For these patients, only bulky extracorporeal or implantable displacement pumps or the total artificial heart have been available to date, which enables only limited quality of life for the patients. It was our goal to evaluate a method that would allow the use of 2 implantable centrifugal left ventricular assist devices as a biventricular assist system. Methods and Results—Seventeen patients have been implanted with 2 HeartWare HVAD pumps, 1 as a left ventricular assist device and 1 as a right ventricular assist device. Seventy-seven percent of the patients had idiopathic dilated or ischemic cardiomyopathy. Their age ranged from 29 to 73 years (mean 51.8 14.5 years), and 11 (64.7%) received intravenous catecholamine support preoperatively. The right ventricular assist device pump was implanted into the right ventricular free wall. The afterload of this pump was artificially increased by local reduction of the outflow graft diameter, and the effective length of its inflow cannula was reduced by the addition of two 5-mm silicon suture rings to the original HVAD implantation ring. All right ventricular assist device devices could be operated in appropriate speed ranges and delivered a flow of between 3.0 and 5.5 L/min. Thirty-day survival was 82%, and 59% of the patients could be discharged home after recovering from the operation. There was no clinically relevant hemolysis in any of the patients. Conclusions—Two HeartWare HVAD pumps can be used as a biventricular assist system. This implantable biventricular support gives the patients more comfort and mobility than usual biventricular ventricular assist devices with large and noisy displacement pumps. (Circulation. 2011;124[suppl 1]:S179–S186.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biventricular circulatory support with two miniaturized implantable assist devices.

BACKGROUND Up to 30% of patients with end-stage heart failure experience biventricular failure that requires biventricular mechanical support. For these patients, only bulky extracorporeal or implantable displacement pumps or the total artificial heart have been available to date, which enables only limited quality of life for the patients. It was our goal to evaluate a method that would allow ...

متن کامل

Ventricular assist devices in pediatrics

The implantation of a mechanical circulatory device for end-stage ventricular failure is a possible therapeutic approach in adult and pediatric cardiac surgery and cardiology. The aim of this article is to present mechanical circulatory assist devices used in infants and children with special emphasis on extracorporeal membrane oxygenation, Berlin Heart assist device, centrifugal pump and Medos...

متن کامل

CASE STUDY Children may survive severe myocarditis with prolonged use of biventricular assist devices

The outcome of acute myocarditis with cardiogenic shock is poor. In some children in whom aggressive medical treatment fails, artificial replacement of heart function may oVer lifesaving support until the myocardium has recovered. Four previously healthy children (three boys aged 4, 6, and 1 years; one girl aged 5) developed acute myocarditis with ventricular failure and multiorgan dysfunction ...

متن کامل

Children may survive severe myocarditis with prolonged use of biventricular assist devices.

The outcome of acute myocarditis with cardiogenic shock is poor. In some children in whom aggressive medical treatment fails, artificial replacement of heart function may offer lifesaving support until the myocardium has recovered. Four previously healthy children (three boys aged 4, 6, and 1 years; one girl aged 5) developed acute myocarditis with ventricular failure and multiorgan dysfunction...

متن کامل

Use of Right Ventricular Support with a Centrifugal Pump in Post-Valve Surgery Right Ventricular Failure: A Case Series

The optimal treatment method for right ventricular failure after valve surgery complicated by a low cardiac output has not been determined, although several case reports have been published on patients with ventricular failure and arrhythmia who were bridged to cardiac transplantation using biventricular or left ventricular assist devices. This case series illustrates successful circulatory sup...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011