The influence of temperature calibration on the OC–EC results from a dual-optics thermal carbon analyzer

نویسندگان

  • J. Pavlovic
  • J. S. Kinsey
  • M. D. Hays
چکیده

Thermal–optical analysis (TOA) is a widely used technique that fractionates carbonaceous aerosol particles into organic and elemental carbon (OC and EC), or carbonate. Thermal sub-fractions of evolved OC and EC are also used for source identification and apportionment; thus, oven temperature accuracy during TOA analysis is essential. Evidence now indicates that the “actual” sample (filter) temperature and the temperature measured by the built-in oven thermocouple (or set-point temperature) can differ by as much as 50 C. This difference can affect the OC–EC split point selection and consequently the OC and EC fraction and sub-fraction concentrations being reported, depending on the sample composition and in-use TOA method and instrument. The present study systematically investigates the influence of an oven temperature calibration procedure for TOA. A dual-optical carbon analyzer that simultaneously measures transmission and reflectance (TOT and TOR) is used, functioning under the conditions of both the National Institute of Occupational Safety and Health Method 5040 (NIOSH) and Interagency Monitoring of Protected Visual Environment (IMPROVE) protocols. The application of the oven calibration procedure to our dual-optics instrument significantly changed NIOSH 5040 carbon fractions (OC and EC) and the IMPROVE OC fraction. In addition, the well-known OC–EC split difference between NIOSH and IMPROVE methods is even further perturbed following the instrument calibration. Further study is needed to determine if the widespread application of this oven temperature calibration procedure will indeed improve accuracy and our ability to compare among carbonaceous aerosol studies that use TOA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of organic carbon, elemental carbon, and water soluble organic carbon concentration in PM2.5 in the ambient air of Sina Hospital district, Tehran, Iran

In the present study, carbon species including organic carbon (OC), elemental carbon (EC), and water-soluble organic carbon (WSOC) concentration in PM2.5 were assessed at an urban site of Tehran, Iran during March to June 2014. The PM2.5 samples were collected using an frmOMNITM Ambient Air Sampler. Thermal gravimetric analysis (TGA) was used to analyze OC and EC. The results showed that PM2.5 ...

متن کامل

Adherence patterns of diarrheagenic Escherichia coli strains isolated from children with gastrointestinal diarrhea and matched controls in a Hep-2 cell adhesion assay

In the present study, carbon species including organic carbon (OC), elemental carbon (EC), and water-soluble organic carbon (WSOC) concentration in PM2.5 were assessed at an urban site of Tehran, Iran during March to June 2014. The PM2.5 samples were collected using an frmOMNITM Ambient Air Sampler. Thermal gravimetric analysis (TGA) was used to analyze OC and EC. The results showed that PM2.5 ...

متن کامل

Multi-wavelength optical measurement to enhance thermal/optical analysis for carbonaceous aerosol

A thermal/optical carbon analyzer equipped with seven-wavelength light source/detector (405–980 nm) for monitoring spectral reflectance (R) and transmittance (T) of filter samples allowed “thermal spectral analysis (TSA)” and wavelength (λ)-dependent organic-carbon (OC)–elementalcarbon (EC) measurements. Optical sensing was calibrated with transfer standards traceable to absolute R and T measur...

متن کامل

A Study on the Mechanical Properties of Dual Phase Steels Prepared by the Direct and Step Quenching Procedure

Two different dual phase steels were prepared from low carbon manganese steel after the elimination of the banding using the direct quenching (DQ) and the step quenching (SQ) procedures. Different heat treatments resulted in different martensite morphologies, microstructures and mechanical properties. The heat treatments were designed in such a way to obtain a 0.25 volume fraction of martensite...

متن کامل

Interactive comment on “ECOC comparison exercise with identical thermal protocols after temperature offsets correction – instrument diagnostics by in-depth evaluation of operational parameters” by P. Panteliadis et al

This manuscript presents an interlaboratory comparison of OC/EC analysis using 2 different thermal protocols and the Sunset carbon analyzer. The study is interesting as it appears to be the first one where all participants use the same thermal protocols. Also discussions on TC/OC/EC quantification in the community are going on for years and any intercomparison is a welcome addition to existing ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014