Impact of an abbreviated protocol for breast MRI in diagnostic accuracy.
نویسندگان
چکیده
PURPOSE We aimed to compare the diagnostic accuracy and interpretation time of an abbreviated protocol relative to the complete protocol of breast magnetic resonance imaging (MRI) with the use of breast imaging reporting and data system (BI-RADS). Between-reader and between-protocol variability for BI-RADS classification and influence of reader expertise on diagnostic accuracies were also evaluated. METHODS We conducted a retrospective reader study in 90 women who underwent breast MRI: 30 benign examinations (graded as American College of Radiology [ACR] 1 or 2), 30 examinations graded as ACR 3 and 30 examinations requiring a histologic proof (graded as ACR 4 or 5). Two radiologists independently reviewed the protocols. The reference standard was 24 months of imaging follow-up (66.6%, n=60), percutaneous biopsy at the 12th month imaging follow-up (5.5%, n=5), and breast surgery (27.9%, n=25). Analysis was done on a per-breast basis. There were 26 cancers in 168 breasts (15.1%) RESULTS: Interpretation time was higher for the complete protocol (mean difference: 84 s, 95% CI [67;101] for senior and 83 s, 95% CI [70;95] for junior reader; P < 0.001). The reliability of BI-RADS classification between both protocols was very good with intraclass correlation coefficient of 0.89 for junior reader and 0.98 for senior reader; the inter-reader reliability was 0.94 and 0.90 for the complete and abbreviated protocols, respectively. For senior reader, the abbreviated and complete protocols yielded 95.1% and 94.4% specificity and 100% sensitivity. CONCLUSION Our data provide corroborating evidence that abbreviated protocols decrease interpretation time without compromising sensitivity or specificity. There was a high level of concordance between the abbreviated and complete protocols and between the two readers.
منابع مشابه
Improving the performance of neural network in differentiation of breast tumors using wavelet transformation on dynamic MRI
ABSTRACT Background: A computer aided diagnosis system was established using the wavelet transform and neural network to differentiate malignant from benign in a group of patients with histo-pathologically proved breast lesions based on the data derived independently from time-intensity profile. Materials and Methods: The performance of the artificial neural network (ANN) was evaluated u...
متن کاملComparison of logistic regression and neural network models in predicting the outcome of biopsy in breast cancer from MRI findings
Background: We designed an algorithmic model based on the logistic regression analysis and a non-algorithmic model based on the Artificial Neural Network (ANN). Materials and methods: The ability of these models was compared together in clinical application to differentiate malignant from benign breast tumors in a study group of 161 patients' records. Each patient’s record consisted of 6 subjec...
متن کاملComparison between MRS and DWI in MRI of breast cancer
Introduction: Breast cancer is the most common cancer in women and is the second leading cause of cancer death (after lung cancer) in people throughout the world. Today, MRI is being used because of the limitations of x-ray mammography to detect breast cancer. Non-contrast sequences were associated to CE sequences in a breast MRI protocol for the sake of appraising morphologic ...
متن کاملDiagnostic Accuracy of Positron Emission Mammography with 18F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size
Objective(s): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size.Methods: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors wa...
متن کاملAbbreviated MRI Protocols for Detecting Breast Cancer in Women with Dense Breasts
OBJECTIVE To evaluate the validity of two abbreviated protocols (AP) of MRI in breast cancer screening of dense breast tissue. MATERIALS AND METHODS This was a retrospective study in 356 participants with dense breast tissue and negative mammography results. The study was approved by the Nanjing Medical University Ethics Committee. Patients were imaged with a full diagnostic protocol (FDP) of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Diagnostic and interventional radiology
دوره 24 1 شماره
صفحات -
تاریخ انتشار 2018