Drug eluting coronary stent: in vitro evaluation of magnet resonance safety at 3 Tesla.

نویسندگان

  • Frank G Shellock
  • John R Forder
چکیده

PURPOSE To evaluate MR safety at 3 Tesla for a drug eluting coronary stent. METHODS A drug eluting coronary stent (Endeavor, cobalt alloy, Medtronic Vascular, Santa Rosa, CA) was evaluated for magnetic field interactions, heating, and artifacts at 3 Tesla. MRI-related heating was assessed with the stent in a gelled saline-filled phantom using a transmit/received RF body coil with a whole body averaged SAR of 2.0 W/kg. Artifacts were characterized using T1-weighted, spin echo, and gradient echo pulse sequences. RESULTS The stent exhibited minor magnetic field interactions that will not cause migration. Heating was not substantial (+0.5 degrees C). Artifacts may create a problem if the area of interest is in the same area or close to the stent (e.g., for a T1-weighted, spin echo pulse sequence, within approximately 16 mm; for a gradient echo pulse sequence, within approximately 23 mm). Conclusion. The findings indicated that it would be safe for a patient with this cobalt alloy-based, drug-eluting coronary stent to undergo MRI at 3 Tesla or less. Importantly, because of the relative lack of magnetic field interactions, MRI may be performed immediately after implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Overview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent

Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...

متن کامل

Association of G22A variant of Adenosine Deaminase gene with coronary in-stent restenosis in coronary artery patients receiving drug-eluting stent

In-stent restenosis (ISR) is regarded as the main problem in the utilization of stents in the treatment of coronary artery atherosclerotic stenosis in percutaneous coronary intervention (PCI). This study investigated the possible role of the G22A variant of the Adenosine Deaminase gene (ADA) in the development of ISR. In this study, 91 patients who underwent PCI were divided into two groups of ...

متن کامل

An advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries

Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...

متن کامل

Safety and Efficacy of New Sirolimus-eluting Stent Models in a Preclinical Study.

INTRODUCTION AND OBJECTIVES Initial preclinical studies are required during the process of improving polymers, platforms, and drug-eluting systems for new coronary stent designs. Our objective was to analyze the efficacy and safety of new drug-eluting stent models compared with a conventional stent and commercialized drug-eluting stents in an experimental model with healthy porcine coronary art...

متن کامل

Optimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique

Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance

دوره 7 2  شماره 

صفحات  -

تاریخ انتشار 2005