Photon Beam Diffusion: A Hybrid Monte Carlo Method for Subsurface Scattering

نویسندگان

  • Ralf Habel
  • Per H. Christensen
  • Wojciech Jarosz
چکیده

We present photon beam diffusion, an efficient numerical method for accurately rendering translucent materials. Our approach interprets incident light as a continuous beam of photons inside the material. Numerically integrating diffusion from such extended sources has long been assumed computationally prohibitive, leading to the ubiquitous single-depth dipole approximation and the recent analytic sum-of-Gaussians approach employed by Quantized Diffusion. In this paper, we show that numerical integration of the extended beam is not only feasible, but provides increased speed, flexibility, numerical stability, and ease of implementation, while retaining the benefits of previous approaches. We leverage the improved diffusion model, but propose an efficient and numerically stable Monte Carlo integration scheme that gives equivalent results using only 3–5 samples instead of 20–60 Gaussians as in previous work. Our method can account for finite and multi-layer materials, and additionally supports directional incident effects at surfaces. We also propose a novel diffuse exact single-scattering term which can be integrated in tandem with the multi-scattering approximation. Our numerical approach furthermore allows us to easily correct inaccuracies of the diffusion model and even combine it with more general Monte Carlo rendering algorithms. We provide practical details necessary for efficient implementation, and demonstrate the versatility of our technique by incorporating it on top of several rendering algorithms in both research and production rendering systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Approximate Reflectance Profiles for Efficient Subsurface Scattering

We present three useful parameterizations of a BSSRDF model based on empirical reflectance profiles. The model is very simple, but with the appropriate parameterization it matches brute-force Monte Carlo references better than state-of-the-art physically-based models (quantized diffusion and photon beam diffusion) for many common materials. Each reflectance profile is a sum of two exponentials ...

متن کامل

Sampling BSSRDFs with non-perpendicular incidence

Sub-surface scattering is key to our perception of translucent materials. Models based on diffusion theory are used to render such materials in a realistic manner by evaluating an approximation of the material BSSRDF at any two points of the surface. Under the assumption of perpendicular incidence, this BSSRDF approximation can be tabulated over 2 dimensions to provide fast evaluation and impor...

متن کامل

A comparative Monte Carlo study on 6MV photon beam characteristics of Varian 21EX and Elekta SL-25 linacs

Background: Monte Carlo method (MC) has played an important role in design and optimization of medical linacs head and beam modeling. The purpose of this study was to compare photon beam features of two commercial linacs, Varian 21EX and Elekta SL-25 using MCNP4C MC code. Materials and Methods: The 6MV photon beams of Varian 21EX and Elekta Sl-25 linacs were simulated based on manufacturers pro...

متن کامل

Thermal-Photon and Residual-Gas Scattering in the NLC Beam Delivery

Without collisions, the largest contribution to the beam lifetime in LEP is Compton scattering off thermal photons. Even if only a few particles are scattered in a single pass, the potential background generated could make this effect important for the NLC as well. We used a modified version of the tracking program DIMAD, which includes a Monte Carlo simulation for the Compton scattering on the...

متن کامل

Monte Carlo calculation of shielding properties of newly developed heavy concretes for megavoltage photon beam spectra used in radiation therapy

Introduction: Globally, the need for radiotherapy as a part of cancer management increases every year. Thus, the shielding for megavoltage radiotherapy rooms is of great importance. Materials and Methods: In the present study, 14 types of developed high-density concrete with densities ranging from 2.45 to 5.11 were simulated by using Monte Carlo method. The linear attenuation coefficient and t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Comput. Graph. Forum

دوره 32  شماره 

صفحات  -

تاریخ انتشار 2013