Use of UV-C radiation to disinfect non-critical patient care items: a laboratory assessment of the Nanoclave Cabinet

نویسندگان

  • Ginny Moore
  • Shanom Ali
  • Elaine A Cloutman-Green
  • Christina R Bradley
  • Martyn AC Wilkinson
  • John C Hartley
  • Adam P Fraise
  • A Peter R Wilson
چکیده

BACKGROUND The near-patient environment is often heavily contaminated, yet the decontamination of near-patient surfaces and equipment is often poor. The Nanoclave Cabinet produces large amounts of ultraviolet-C (UV-C) radiation (53 W/m2) and is designed to rapidly disinfect individual items of clinical equipment. Controlled laboratory studies were conducted to assess its ability to eradicate a range of potential pathogens including Clostridium difficile spores and Adenovirus from different types of surface. METHODS Each test surface was inoculated with known levels of vegetative bacteria (10(6) cfu/cm(2)), C. difficile spores (10(2)-10(6) cfu/cm(2)) or Adenovirus (10(9) viral genomes), placed in the Nanoclave Cabinet and exposed for up to 6 minutes to the UV-C light source. Survival of bacterial contaminants was determined via conventional cultivation techniques. Degradation of viral DNA was determined via PCR. Results were compared to the number of colonies or level of DNA recovered from non-exposed control surfaces. Experiments were repeated to incorporate organic soils and to compare the efficacy of the Nanoclave Cabinet to that of antimicrobial wipes. RESULTS After exposing 8 common non-critical patient care items to two 30-second UV-C irradiation cycles, bacterial numbers on 40 of 51 target sites were consistently reduced to below detectable levels (≥ 4.7 log10 reduction). Bacterial load was reduced but still persisted on other sites. Objects that proved difficult to disinfect using the Nanoclave Cabinet (e.g. blood pressure cuff) were also difficult to disinfect using antimicrobial wipes. The efficacy of the Nanoclave Cabinet was not affected by the presence of organic soils. Clostridium difficile spores were more resistant to UV-C irradiation than vegetative bacteria. However, two 60-second irradiation cycles were sufficient to reduce the number of surface-associated spores from 10(3) cfu/cm(2) to below detectable levels. A 3 log10 reduction in detectable Adenovirus DNA was achieved within 3 minutes; after 6 minutes, viral DNA was undetectable. CONCLUSION The results of this study suggest that the Nanoclave Cabinet can provide rapid and effective disinfection of some patient-related equipment. However, laboratory studies do not necessarily replicate 'in-use' conditions and further tests are required to assess the usability, acceptability and relative performance of the Nanoclave Cabinet when used in situ.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Legionella Control Options by UV and Violet LEDs for Hospitals and Care Facilities

Legionella infections caused by contaminated water are a widespread problem worldwide. Discharge lamps like mercury vapor lamps are widely known for the disinfection properties of their radiation, but they suffer technical disadvantages, like high voltages and toxic content, and are, therefore, not suitable for some infection control applications. New high-intensity ultraviolet (UV) an...

متن کامل

Estimating the radiation dose of non-radiation workers from nuclear medicine patients

Introduction: As a valuable imaging modality, Nuclear Medicine (NM) indications is raising in clinical practice. The remained portion administrated radioactive material in patients’ tissues is a critical issue, especially when the procedure is performed in hospitalized patients, where the non-radiation workers present. The aim of this study was evaluation the dose of non-radia...

متن کامل

Development and statistical assessment of a radiation safety literacy measurement tool

Background: The publicchr('39')s understanding of radiation and protection of radiation harm is not high. Therefore, it is meaningful to know the radiation safety literacy level in terms of health care. This study developed a measurement tool that can help to identify the actual condition of radiation safety literacy and conducted the statistical assessment of the developed tool. Materials and ...

متن کامل

Comparison of Ultraviolet Protection Factor of Pure Cotton and Cotton Coated with Titanium Dioxide Nanoparticles using the Electrospinning Method with Two Ultraviolet-C Generators

Introduction: Protection against harmful effects of ultraviolet radiation (UV) is measured under Ultraviolet Protection Factor (UPF) scale. The utilization of protective clothing is the best way to deal with the damage caused by ultraviolet radiation. The purpose of this study was to compare the ultraviolet ray protective factor of pure cotton and cotton coated with ti...

متن کامل

The dimensions of clinical competence of nurses working in critical care units and their relation with the underlying factors

Introduction: Clinical competency is the use of skillful, technical and communication skills, knowledge, clinical reasoning, emotions and values in clinical settings. Developing the professional competence of investment nurses to ensure the safety and quality of patient care. The factors influencing the clinical competence of experience, environment, and the use of opportunities, motivation, th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012