High-resolution spectroscopy of the Î1⁄28 band of methylene bromide using a quantum cascade laser

نویسندگان

  • Brian E. Brumfield
  • Jacob T. Stewart
  • Benjamin J. McCall
چکیده

0022-2852/$ see front matter 2011 Elsevier Inc. A doi:10.1016/j.jms.2011.02.013 ⇑ Corresponding author. E-mail address: [email protected] (B.J. McCall) A continuous wave cavity ringdown spectrometer with a Fabry-Perot quantum cascade laser has been used to collect a rotationally-resolved infrared spectrum of the m8 vibrational band of methylene bromide in a slit nozzle expansion. In our laboratory, previous observations of the vibrational band were limited by spectral coverage to only the P and Q-branches and by the 24 MHz step-size of the laser [1]. The issue of limited spectral coverage has been resolved using a Fresnel rhomb and a wire grid polarizer to protect the laser from the destabilizing effects of back-reflection from the ringdown cavity. The frequency stepsize of the spectrometer has been reduced from 24 MHz to 2 MHz. With both of these instrument enhancements, we have been able to record the R-branch of the vibrational band, and can resolve many lines that were previously blended in spectra acquired using a pinhole expansion nozzle. Significant hyperfine splitting was observed for the low-J transitions in the P and R-branches. It was possible to neglect the effects of hyperfine splitting for transitions involving J00 > 2 in the spectral assignment, and simulations using the constants obtained by fitting to Watson’s S-reduced Hamiltonian for CH2BrBr, and the A-reduced form for CH2 Br2 and CH2 Br2, provide a good match to experimental spectra. A total of 297 transitions have been assigned for all three isotopologues, with a standard deviation of 0.00024 cm ( 7 MHz). 2011 Elsevier Inc. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-Resolution Gas Phase Infrared Spectroscopy of Water Clusters and Cluster Ions Using Quantum Cascade Lasers

A continuous wave cavity ringdown spectrometer with a Fabry-Perot quantum cascade laser has beenused to collect a rotationally-resolved infrared spectrum of them8 vibrational band of methylene bromidein a slit nozzle expansion. In our laboratory, previous observations of the vibrational band were limitedby spectral coverage to only the P and Q-branches and by the 24 MHz step-siz...

متن کامل

Temperature Effect on THz Quantum Cascade Lasers

A simple semi-phenomenological model, which accurately predicts the dependence of thresholdcurrent for temperature of Resonant-phonon three well quantum cascade laser based on verticaltransitions is offered. We found that, the longitude optical phonon scattering of thermally excitedelectrons is the most important limiting factor for thermal performance of high frequency THz QCLs.In low frequenc...

متن کامل

HIGH RESOLUTION LASER SPECTROSCOPY IN COLD SUPERSONIC MOLECULAR BEAMS COOLING, REDUCTION OF DOPPLER WIDTH AND APPLICATION

The cooling of molecules during the adiabatic expansion of supersonic seeded molecular beams is reviewed and illustrated by the example of NO -molecules. The reduction of the Doppler width by collimation of the beam and the cooling to low rotational temperatures brings a significant simplification of the complex NO -absorption spectrum and allows its assignment. The measured rotational tem...

متن کامل

pH Effect on the Size of Graphene Quantum dot Synthesized by Using Pulse Laser Irradiation

In this study graphene oxide (GO) was synthesized by using Hummer’s method. Low dimension graphene quantum dot nanoparticles (GQDs) were synthesized using pulse laser irradiation. Fourier Transform-Infrared Spectroscopy (FTIR), Ultraviolet-Visible (UV-Vis) spectroscopy and photoluminescence (PL) analysis were applied to study the GQDs characteristic. Scanning electron microscopy illustrated the...

متن کامل

Characterization of mid-infrared quantum cascade lasers

Quantum cascade lasers provide some of the highest output powers available for light in the mid-infrared range (from 3 to 8 μm). As many of their applications require portability, designs that have a high wall-plug efficiency are essential, and were designed and grown by others to achieve this goal. However, because a large fraction of these devices did not operate at all, very few of the stand...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011