Minimizing the surface effect of PDMS–glass microchip on polymerase chain reaction by dynamic polymer passivation

نویسندگان

  • Yong-Mei Xia
  • Zhi-Shan Hua
  • Onnop Srivannavit
  • Ayse Bilge Ozel
  • Erdogan Gulari
چکیده

Polydimethyl siloxane (PDMS)–glass microchip has a very strong surface effect on polymerase chain reaction (PCR), leading to a very poor PCR yield. In the work reported here, practical dynamic passivation of surfaces of PDMS–glass microchip using polyethylene glycol (PEG) or polyvinylpyrrolidone (PVP) was achieved using a conventional thermocycler. The passivation procedure was cost-effective and easy to conduct. The effects of polymer molecular weight and polymer concentration on tube PCR efficiency were investigated primarily to prescreen out suitable polymers and polymer concentrations in the PCR mixture. The result from tube PCR indicated that both PEG and PVP could affect the performance of Taq polymerase. A final concentration of 0.025% (w/v) or 0.4% (w/v) polymer in the PCR mixture can enhance the tube PCR, while 1% (w/v) polymer was found to inhibit the reaction. PEG was more effective in tube PCR, although PVP performed better in chip PCR. Instead of employing the polymer directly in the PCR mixture, i.e. the conventional in situ passivation approach, another approach of dynamic passivation by pre-injecting polymers into the microchip achieved better performance. The efficiency of pre-passivation was found to follow the order: PVP10000>PVP55000, PEG8000> PEG10000>PEG400. After pre-passivation with PVP10000, PVP55000 and PEG8000, the PCR efficiency can recover to 93%, 86% and 83%, respectively, of that obtained from tube PCR.  2006 Society of Chemical Industry

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Increased amplification efficiency of microchip-based PCR by dynamic surface passivation.

Surface passivation is critical for effective PCR using silicon-glass chips. We tested a dynamic polymer-based surface passivation method. Polyethylene glycol 8000 (PEG 8000) or polyvinylpyrrolidone 40 (PVP-40) applied at 0.75% (w/v) in the reaction mixture produced significant surface passivation effects using either native or SiO2-precoated silicon-glass chips. PCR amplification was achieved ...

متن کامل

Mutation detection using ligase chain reaction in passivated silicon-glass microchips and microchip capillary electrophoresis.

The ligase chain reaction (LCR) following PCR is one of the most sensitive and specific methods for detecting mutations, especially single nucleotide polymorphisms (SNPs). Performing LCR in microchips remains a challenge because of the inhibitory effect of the internal surfaces of silicon-glass microchips. We have tested a dynamic polymer-based surface passivation method for LCR conducted in ox...

متن کامل

Dynamic Passivation with BSA Overcomes LTCC Mediated Inhibition of PCR

The increasing use of low temperature co-fired ceramic (LTCC) for the fabrication of biological microfluidic devices necessitates further research on LTCC biocompatibility. In this study we explore the inhibitory effect of DuPont’s 951 LTCC on Polymerase Chain Reaction (PCR), and demonstrate a novel mechanism to increase biocompatibility between LTCC and PCR with the addition of a common passiv...

متن کامل

Acoustothermal heating of polydimethylsiloxane microfluidic system

We report an observation of rapid (exceeding 2,000 K/s) heating of polydimethylsiloxane (PDMS), one of the most popular microchannel materials, under cyclic loadings at high (~MHz) frequencies. A microheater was developed based on the finding. The heating mechanism utilized vibration damping in PDMS induced by sound waves that were generated and precisely controlled using a conventional surface...

متن کامل

Digital polymerase chain reaction in an array of femtoliter polydimethylsiloxane microreactors.

We developed a simple, compact microfluidic device to perform high dynamic-range digital polymerase chain reaction (dPCR) in an array of isolated 36-femtoliter microreactors. The density of the microreactors exceeded 20000/mm(2). This device, made from polydimethylsiloxane (PDMS), allows the samples to be loaded into all microreactors simultaneously. The microreactors are completely sealed thro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -