Effective Renal Plasma Flow Determination Using Technetium·
نویسنده
چکیده
Previous studies have suggested that by slight modification of the cu"entformulosfor iodine-131 (1) orthoiodohippurate (OIH) effective renal plasma flow (ERPF) quantitation, technetium99m ('mTc) mercaptoacetyltriglycine (MAG~ can be substituted for 1-0IH in the quantitative renal function protocol. This study was undertaken to compare two different camera techniques that do not require blood samples. The Schlegel camera method, modified by the introduction of 0.67 as a co"ection factor, comprised one technique. In the other technique, the renal clearance (RC) was determined and then converted to ERPF. The results were then compared with the Tauxe (TX) method. Fifty patients with varying degrees of renal impairment were studied. Our comparative results support the concept that a camera technique can be applied to 9mTc-MAG3 to determine ERPF, with results similar to those obtained by the Tauxe method (p < 0.01).
منابع مشابه
Off-site determinations of effective renal plasma flow using technetium-99m-MAG3 and single blood sampling.
UNLABELLED This study evaluated the feasibility of determining effective renal plasma flow (ERPF) at an off-site central laboratory by transferring blood samples from the on-site laboratory. METHODS Blood samples were obtained from 66 patients referred for renal imaging with 99mTc-MAG3. ERPF values were determined using the single blood sample method (BSM) at both on- and off-site laboratorie...
متن کاملComparison of Technetium-99m MAG3TM and lodine-131 OIH ERPF Results Using the Camera Technique
Recent studies have suggested that technetium-99m (19mTc) MAG3 can be substituted for iodine-131 ( 131 I) OIH, with better image quality and lower radiation dose. This study compares the two radiopharmaceuticals for effective renal plasma flow (ERPF) results using only the camera method. Twenty patients with varying degrees of renal impairment were studied. In 13 of these patients, direct compa...
متن کاملComparison of Technetium-99m MAG3TM and lodine-131 OIH ERPF Results Using the Camera Technique
Recent studies have suggested that technetium-99m (19mTc) MAG3 can be substituted for iodine-131 ( 131 I) OIH, with better image quality and lower radiation dose. This study compares the two radiopharmaceuticals for effective renal plasma flow (ERPF) results using only the camera method. Twenty patients with varying degrees of renal impairment were studied. In 13 of these patients, direct compa...
متن کاملThe Estimation of Renal Function with 99 m Tc - DTPA and 99 m Tc - MAG 3
The estimation of glomerular filtration rate and effective renal plasma flow based on camera-based methods for diagnostic and prognostic are studied by manually ROIs drawing on dynamic renal scintigraphy. The manually ROIs drawing may reduce the convenience and reliability. This paper proposes a estimation of glomerular filtration rate and effective renal plasma flow based on camera-based metho...
متن کاملClinical Studies Effective Renal Plasma Flow Response and Atrial Natriuretic Peptide in Patients with Uncomplicated Acute Myocardial Infarction
Effective renal plasma flow was determined by using I-131 labeled iodo-ortho-hippurate in 17 Chinese patients admitted to the coronary care unit with uncomplicated acute myocardial infarction. The first determination, immediately after admission, was significantly higher than the second determination done a week later, 444.5•}153.9 vs. 371.1•}124.9 ml/min (p<0.02). The initial rise of effective...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -