Validation of lamellar body counts using three hematology analyzers.

نویسندگان

  • Christina M Lockwood
  • J Chance Crompton
  • Joan K Riley
  • Keith Landeros
  • Dennis J Dietzen
  • David G Grenache
  • Ann M Gronowski
چکیده

The lamellar body count (LBC) represents an alternative method to the TDx-FLM II (Abbott Laboratories, Abbott Park, IL), which is planned to be discontinued, for assessing fetal lung maturity. Our objective was to validate the LBC on 3 hematology analyzers (Coulter LH 750 and Coulter Ac.T diff2, Beckman Coulter, Brea, CA; and Sysmex XE-2100, Sysmex, Mundelein, IL) to serve as a template for other laboratories attempting to perform in-house validation. Intra-assay and interassay coefficients of variation ranged from 1.7% to 21.8% and 1.9% to 7.1%, respectively, and all analyzers demonstrated excellent linearity. Whole blood and meconium were shown to interfere with LBCs, and specimens with these contaminants should be tested using phosphatidyl glycerol. With a TDx-FLM II cutoff of 55 mg/g or more and an LBC cutoff of 50,000/microL or more for maturity, concordance between the TDx-FLM II and the LBC on all instruments was poor (<80% in all cases). Concordance between hematology analyzers was excellent (>or=94%). When laboratories are performing in-house validations, they should not correlate LBC with TDx-FLM II results without outcome data. Correlation with another validated LBC method is preferred.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peykan check, a simple continuous quality control method for hematology analyzers

A simple inexpensive con!nuous quality control method, by means of eight basic blood coun!ng parameters, obtained from automated hematology analyzers, using pa!ent samples, is described. A few samples with low, normal and high values were selected and introduced to the instrument early in the morning as the first count, the results of which are plo#ed on the appropriate chart as dots. The sa...

متن کامل

White blood cell differential counts in severely leukopenic samples: a comparative analysis of different solutions available in modern laboratory hematology

BACKGROUND We evaluated the efficacy of white blood cell (WBC) differential counts in severely leukopenic samples by the Hematoflow method and by automated hematology analyzers and compared the results with manual counts. METHODS EDTA-anticoagulated blood samples (175 samples) with WBC counts of 40-990/µL were selected. Hematoflow differential counts were performed in duplicates employing flo...

متن کامل

Producing accurate platelet counts for platelet rich plasma: validation of a hematology analyzer and preparation techniques for counting.

Platelet rich plasma (PRP) has been shown to clinically accelerate healing of both soft and hard tissues. As a result, it has gained increasing popularity. However, the clinical effectiveness of each type of PRP preparation method can vary in technique and efficiency, and current methods to evaluate the platelet concentration efficiency of PRP systems have several limitations. Therefore, the pu...

متن کامل

Leukocyte counts in cerebrospinal fluid with the automated hematology analyzer CellDyn 3500 and the urine flow cytometer UF-100.

BACKGROUND The counting of leukocytes and erythrocytes in cerebrospinal fluid (CSF) is still performed microscopically, e.g., using a chamber in most laboratories. This requires sufficient practical experience, is time-consuming, and may constitute a problem in emergency diagnostics. Specific automated systems for CSF cell counting are not available at present. METHODS We tested the hematolog...

متن کامل

Evaluation of the pocH-100iV DIFF hematology analyzer for use in horses and cattle Evaluatie van de pocH-100iV DIFF-hematologie analyzer voor paarden- en runderbloed

The results of the analysis of equine and bovine blood samples with the automated pocH-100iV DIFF hematology analyzer were compared with the results obtained with reference methods or other analyzers (Vet ABC, Coulter Counter ZF, Coulter LH 750 analyzer). For equine blood and most parameters in bovine blood good to excellent correlations between methods and analyzers were obtained. For bovine b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 134 3  شماره 

صفحات  -

تاریخ انتشار 2010