The Combined Application of Impinger System and Permeation Tube for the Generation of Volatile Organic Compound Standard Gas Mixtures at Varying Diluent Flow Rates

نویسندگان

  • Ki-Hyun Kim
  • Janice Susaya
  • Jinwoo Cho
  • David Parker
چکیده

Commercial standard gas generators are often complex and expensive devices. The objective of this research was to assess the performance of a simplified glass impinger system for standard gas generation from a permeation tube (PT) device. The performance of the impinger standard gas generation system was assessed for four aromatic VOCs (benzene, toluene, ethylbenzene, and m-xylene; BTEX) at varying flow rates (FR) of 50 to 800 mL·min(-1). Because actual permeation rate (APR) values deviated from those computed by the manufacturer's formula (MPR), new empirical relationships were developed to derive the predicted PR (PPR) of the target components. Experimental results corrected by such a formula indicate that the compatibility between the APR and MPR generally increased with low FR, while the reproducibility was generally reduced with decreasing flow rate. Although compatibility between different PRs is at a relatively small and narrow FR range, the use of correction formula is recommendable for the accurate use of PT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using thermogravimetry for weight loss monitoring of permeation tubes used for generation of trace concentration gas standards.

Permeation tubes are convenient analyte sources for generating standard gas mixtures (containing, in particular, volatile organic compounds) used in the calibration of analytical instruments. For small permeation rates, corresponding to trace levels of analytes, the calibration of permeation tubes is time-consuming. The use of thermogravimetry as a means to measure rapidly the weight loss at co...

متن کامل

A microporous membrane-based continuous generation system for trace-level standard mixtures of atmospheric gases.

A reliable and convenient system to generate accurate and stable standard gas mixtures of various atmospheric compounds at parts-per-billion levels has been developed. The system is of simple design; the generator is a coil consisting of an inner tube of microporous polytetrafuluoroethylene (PTFE) membrane tubing and an outer tube of silicone tubing. An aqueous solution of the given compound co...

متن کامل

Technical-economic analysis of the combined system power generation, production of fresh water and cooling production

In gas power plants, a lot of energy is lost in the form of heat more than the electricity produced. In the present research, techno-economic evaluation of combined power, desalination and cooling systems running by the exhaust flue gases of a gas turbine in Iran is performed. In addition to using power generated by the gas turbine, attempts were made to use Organic Rankine Cycle to recover the...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012