Normal values of M mode echocardiographic measurements of more than 2000 healthy infants and children in central Europe.

نویسندگان

  • C Kampmann
  • C M Wiethoff
  • A Wenzel
  • G Stolz
  • M Betancor
  • C F Wippermann
  • R G Huth
  • P Habermehl
  • M Knuf
  • T Emschermann
  • H Stopfkuchen
چکیده

OBJECTIVE To obtain normal M mode (one dimensional) echocardiographic values in a substantial sample of normal infants and children. DESIGN Data were obtained over three years from a single centre in central Europe. PATIENTS 2036 healthy infants and children aged one day to 18 years. METHODS In line with recommendations for standardising measurements from M mode echocardiograms, and using digital echocardiographic equipment, measurements were obtained of the following: right ventricular anterior wall thickness at end diastole, right ventricular end diastolic dimension, thickness of interventricular septum at end diastole and end systole, thickness of posterior wall of the left ventricle at end diastole and end systole, left ventricular dimension at end diastole and end systole, pulmonary and aortic valve diameter, and left atrial dimension. RESULTS Measurements are presented graphically on centile charts with respect to body surface area, and as tables with mean and 2 SD values for newborns in relation to body weight, and for infants and children in relation to body surface area. Best fitting regression equations are given for each measured variable, using the 50th centile values. CONCLUSION In comparison with previously published normal values, the presented charts and tables make it possible to judge echocardiographic measurements of a particular patient as normal or abnormal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reference values of M-mode echocardiographic parameters and indices in conscious Labrador Retriever dogs

Breed-wise standard echocardiographic values in dogs have been reported as there is variation in body and chest conformation which limits the application of data of one breed for other breed. Labrador Retrievers being originated from hunting dogs, might have different echocardiographic values from standard normal range of other dog breeds. So, the present study was aimed to determine the M-mode...

متن کامل

Echocardiographic Measurement of Systolic Time Intervals in Healthy Great Dane Dogs

Objective- to determine the range of systolic times intervals using Pulsed-wave Doppler and m-mode echocardiography in normal, healthy Great Dane dogs. Design- Descriptive study. Animals- Thirty healthy Great Dane dogs. Procedures- This study examined 30 clinically healthy Great Dane dogs by the twodimensional, M-mode and Pulsed-wave Doppler echocardiography. The dogs were awake and unsedated. ...

متن کامل

Normal M mode values in healthy Turkish children.

AIM Evaluation of cardiac structures requires a large study group for accurate data on normal values. The aim of the study was to obtain normal M mode echocardiographic values in a substantial sample of healthy term neonates and children to develop centile charts. MATERIALS AND METHODS Data were obtained over 2 years from a single center in Turkey, from 1200 healthy infants and children aged ...

متن کامل

Normal Echocardiographic Findings in Healthy Pigeons

Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...

متن کامل

DOPPLER-DERIVED RIGHT VEN T RICU L AR MYOC ARD IAL PERFORMANCE IN DEX IN NEON ATES: N ORMAL VALUES

Doppler-derived myocardial performance index (MPI) , defined as the s um of isovolumetric contraction and relaxation durations divided by ejection time, is an easily measured and reproducible index that shows both systolic and diastolic myocardial function. The goal of this study was to define normal values of right ventricular MPI in neonates in the first 48 to 72 hours of life. Fifty-one...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 83 6  شماره 

صفحات  -

تاریخ انتشار 2000