Comparison of six dilute russell viper venom time lupus anticoagulant screen/confirm assay kits.
نویسندگان
چکیده
BACKGROUND The normalized dilute Russell viper venom time (DRVVT) ratio provides a robust assay methodology for lupus anticoagulant (LA) detection. OBJECTIVES We evaluated six normalized DRVVT LA screen and confirm systems for inter-method consistency. Reagents were purchased from Diagnostica Stago, Inc. (Parsippany, NJ); Precision BioLogic Inc. (Halifax, Nova Scotia, Canada); Siemens Healthcare Inc. (Deerfield, IL); TCoag (Parsippany, NJ); Instrumentation Laboratories (Bedford, MA); and Sekisui Diagnostics (Pfungstadt, Germany). METHODS For all assays, we employed the STA-R Evolution automated coagulometer, adhering to manufacturers' instructions. LA-positive and LA-negative plasma controls were purchased from Diagnostica Stago and pooled normal plasma (PNP) was purchased from Precision BioLogic. We computed the mean of the reference interval (MRI) and action limits for all kits using LA-negative aliquots from locally sourced normal subjects (n = 42). We then assayed locally sourced LA-positive plasmas (n = 43) and using analysis of variance compared uncorrected screen/confirm ratios and screen/confirm ratios that were normalized using MRI and mean PNP results. RESULTS The grand mean action limit, MRI + 3 SD, derived from the local normal plasmas, was 1.2, confirming the manufacturers' recommended limits; however, limits must be locally computed. The all-sample p value was less than 0.001, indicating heterogeneity among ratios. When Sekisui ratios were excluded, the p value was 0.14, thus indicating that this method introduced the major difference among methods. Mean screen/confirm ratios computed from LA-positive specimens were 1.91 to 2.04 for reagent systems other than Sekisui, which instead yielded a mean ratio of 1.198, indicating that this method was relatively insensitive to LA. A negative bias was recorded by two lots from the Sekisui system for LA-positive specimens. Screen/confirm ratios from combined LA-positive and LA-negative samples generated a combined range of 1.59 to 1.67 for all reagents except Sekisui, which instead yielded 1.09. The within-run percent coefficient of variation (CV%) was less than 5.0% using all samples. Between-run CV% using Diagnostica Stago LA-positive and LA-negative controls was less than 5.5%. CONCLUSIONS DRVVT screen/confirm ratios discriminate between LA-positive and LA-negative samples and generally provide acceptable reproducibility. Ratio results may vary among reagent-instrument combinations. In this study, normalization added little to the clinical result interpretation.
منابع مشابه
Combining Taipan snake venom time/Ecarin time screening with the mixing studies of conventional assays increases detection rates of lupus anticoagulants in orally anticoagulated patients
BACKGROUND Oral anticoagulation compromises conventional lupus anticoagulant (LA) screening assays. Mixing studies can counteract the oral anticoagulant effect but the dilution reduces sensitivity and can generate false negative results. A firm diagnosis can be made from mixing studies when an elevated screen ratio is accompanied by a confirm ratio that generates significant correction to demon...
متن کاملProspective study of fluctuations of lupus anticoagulant activity and anticardiolipin antibody titre in patients with systemic lupus erythematosus.
Fluctuations of lupus anticoagulant activity and anticardiolipin antibody titres were studied in 53 patients with systemic lupus erythematosus (SLE). The median study time was 26 months with a median number of 12 samples. Lupus anticoagulant was measured by the kaolin clotting time (KCT) and dilute Russell viper venom time (dRVVT) assays; anticardiolipin antibodies were assayed by an enzyme lin...
متن کاملPresence of direct thrombin inhibitors can affect the results and interpretation of lupus anticoagulant testing.
In vitro experiments were conducted to determine whether the direct thrombin inhibitors argatroban and lepirudin can interfere with the results of lupus anticoagulant (LA) testing. Concentration-response curves were generated to calculate the concentration of anticoagulant that prolongs the activated partial thromboplastin time (aPTT) to 75 seconds (2.5 times the baseline average). Correspondin...
متن کاملRecent guidelines and recommendations for laboratory detection of lupus anticoagulants.
The International Society on Haemostasis and Thrombosis (ISTH) and the British Committee for Standards in Haematology (BCSH) have recently updated their lupus anticoagulant (LA) detection guidelines. The Clinical and Laboratory Standards Institute (CLSI) subsequently will publish its first LA guideline. General agreement exists on issues such as sample preparation, the use of dilute Russell vip...
متن کاملLupus anticoagulant and anticardiolipin antibodies in SLE with secondary Antiphospholipid Antibody Syndrome.
Thirty patients with systemic lupus erythematosus (SLE) and suspected secondary antiphospholipid antibody syndrome (APLAS) were evaluated in the study based on their clinical manifestations. The aim was to study the prevalence of various antiphospholipid antibodies, compare the tests used for their detection and to find a correlation between clinical and laboratory parameters. Coagulation tests...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Seminars in thrombosis and hemostasis
دوره 39 3 شماره
صفحات -
تاریخ انتشار 2013