Accurate Differentiation of Streptococcus pneumoniae from other Species within the Streptococcus mitis Group by Peak Analysis Using MALDI-TOF MS
نویسندگان
چکیده
Despite the benefits of MALDI-TOF MS technology (Matrix-Assisted Laser Desorption-Ionization Time-Of-Flight Mass Spectrometry) reported worldwide and the continuous improving of the available databases, discrimination between Streptococcus pneumoniae and closely related species within the Streptococcus mitis group (SMG) using this methodology has been suboptimal. However, the accurate identification at the species level of this group of microorganisms is important for the appropriate management of infected patients. In this study, 216 SMG isolates -101 S. pneumoniae and 115 corresponding to 7 non-pneumococcal species within this group- were analyzed. All the isolates had been previously identified by conventional methods (optochin and bile solubility tests) and non-pneumococcal isolates were confirmed by sequence analysis (sodA and plys genes) when required. The isolates were also identified with the MALDI Biotyper 3.1 (Bruker Daltonics, Bremen, Germany) using an updated library containing 6,903 Main Spectra Profiles (MSPs). All the analyzed S. pneumoniae were correctly identified with MALDI-TOF MS at species level using the most updated database and all the non-pneumococcal SMG isolates were also identified at the group level. Several peaks (4,964.32, 6,888.90, and 9,516.46 m/z) have been found to be specific of S. pneumoniae, whilst a different set of peaks have proved to be present only in S. mitis (6,839.07 m/z) and S. oralis (5,297.61, 5822.53, and 6,839.07 m/z). Peak analysis allowed correct species assignment of 101/101 S. pneumoniae isolates (100%) and 102/105 S. mitis/oralis isolates (97.1%). Thus, the implementation of MALDI-TOF MS plus peak analysis for the identification of this group of microorganisms may provide precise species-level information that will allow the early implementation of directed antibiotic therapy.
منابع مشابه
Comparison of MALDI TOF with conventional identification of clinically relevant bacteria.
BACKGROUND A completely new approach to diagnose microbial agents at least one day earlier based on mass spectrometric analysis becomes possible in the microbiology laboratory: MALDI TOF: matrix-assisted laser desorption/ionisation time-of-flight. Comparison between results of the new procedure with those obtained by conventional testing is mandatory. METHODS 204 clinical isolates grown on ag...
متن کاملIdentification of clinical Streptococcus pneumoniae isolates among other alpha and nonhemolytic streptococci by use of the Vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry system.
Discrimination between Streptococcus pneumoniae and its close relatives of the viridans group is a common difficulty in matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry-based identification. In the present study, the performances of the Vitek MS MALDI-TOF mass spectrometry system were assessed using 334 pneumococci, 166 other S. mitis group streptococci, ...
متن کاملCorrect implementation of matrix-assisted laser desorption ionization-time of flight mass spectrometry in routine clinical microbiology.
As we have been users of matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) since January 2009, we read with much interest the paper of van Veen et al. (9) in a recent issue of the Journal of Clinical Microbiology. We would like to respond to two issues addressed in this article as well as in that of Seng et al. (5) published in Clinical Infectious Disea...
متن کاملViridans Group Streptococci Clinical Isolates: MALDI-TOF Mass Spectrometry versus Gene Sequence-Based Identification
Viridans Group Streptococci (VGS) species-level identification is fundamental for patients management. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been used for VGS identification but discrimination within the Mitis group resulted difficult. In this study, VGS identifications with two MALDI-TOF instruments, the Biotyper (Bruker) and the VITEK ...
متن کاملUsing Matrix-Assisted Laser Desorption Ionization-Time of Flight (MALDI-TOF) Complemented with Selected 16S rRNA and gyrB Genes Sequencing to Practically Identify Clinical Important Viridans Group Streptococci (VGS)
There are challenges in viridans group streptococci (VGS) identification especially for the mitis group. Few studies have investigated the performance of MALDI-TOF MS system in VGS identification. Using 16S rRNA gene and gyrB gene sequencing as a gold standard, the performance of two MALDI-TOF MS instruments in the identification of 181 VGS clinical isolates was studied. The Bruker Biotyper and...
متن کامل