A new modification of the Chiron ACS assay for total prostate-specific antigen achieves equimolar response characteristics and improves the detection of prostate cancer.
نویسندگان
چکیده
Nonequimolar-response assays for prostate-specific antigen (PSA) are criticized for overestimating total PSA in some men without prostate cancer (PCA), and underestimating total PSA in some men with PCA. We recently studied three nonequimolar-response PSA assays that had undergone modifications. While two of the studied assays achieved equimolar-response characteristics with improved areas under receiver operating characteristic (ROC) curves (AUC), the modification of the Chiron ACS PSA assay (ACS PSA2, Chiron) failed to achieve this. Recently, the ACS assay underwent another modification (ACS PSA, Bayer), which we investigated. Sera from 305 men (155 without and 150 with PCA, PSA > or = 2 and < or = 30 microg/l, Tandem-E) were measured using both modifications of the ACS assay and equimolar-response reference methods (Tandem-R free and Tandem-E, Hybritech). Molar response relative to the reference method and clinical performance (comparison of AUCs) between the previous and new ACS assay modifications were studied. The new modification of the ACS assay (ACS PSA, Bayer) achieved equimolar-response characteristics but reported lower values (average 10%) than the Tandem-E assay. Compared to the previous modification (ACS PSA2, Chiron), a 3% improvement in AUC (p = 0.01) was found. Using results of the redesigned equimolar-response assay (ACS PSA, Bayer), we calculated that 6 of 155 men without PCA in this sample set could be spared unnecessary biopsy compared with the previous nonequimolar-response assay (ACS PSA2, Chiron) without missing additional PCA (90% sensitivity). These data provide additional evidence for clinical advantages of equimolar-response over nonequimolar-response PSA assay formats.
منابع مشابه
Designing a Radioimmunometric Assay Kit for Prostate-Specific Antigen Measurement Using Polystyrene Tubes Coated By Immunochemical Method
ABSTRACT Background and Objective: Prostate specific antigen (PSA) is considered as one of the most reliable biomarkers of cancer and other known prostate diseases. In the present study, solid phase sandwich immunoradiometric assay was used to measure the amount of PSA. In this type of measurement, a pair of anti-PSA antibodies on the solid phase and la...
متن کاملWhat is the most appropriate test in detecting prostate cancer in patients with intermediate prostate specific antigen levels?
Abstract Background: Regarding the variety of tests present for detecting and also screening prostate cancer and also bearing in mind the advantages and disadvantages of these tests we decided to re-evaluate these tests (total prostate specific antigen and all of its modifications) in detecting prostate cancer in men with intermediate serum PSAlevels. Methods: Following a cross se...
متن کاملCan Prostate Specific Antigen Be Used as New Biomarker for Early Diagnosis of Breast Cancer?
Introduction: As a glycoprotein, Plasma Prostate-Specific Antigen (PSA) is mainly produced by prostate epithelial cells and is used as a major diagnostic tool for prostate cancer. A group of researchers relate the elevated number of estrogen receptors in breast cancer samples to the over-production of PSA in this type of cancer. Therefore, the present study aimed to determine the participants' ...
متن کاملAge Specific Reference Levels of Serum Prostate-Specific Antigen, Prostate Volume and Prostate Specific Antigen Density in Healthy Iranian Men
Background: It is relevant to highlight that there is not a precise and perfect report on either 95 percentile value (upper limit of normal range) or on appropriate reference intervals for serum PSA in Iranian population. Objective: To determine age-specific reference ranges for serum prostate-specific antigen (PSA) concentration and PSA density (PSAD) and prostate volumes in a population of he...
متن کاملتشخیص آنتیژن اختصاصی پروستات با استفاده از بیوسنسور الکتروشیمیایی مبتنی بر آپتامر
Background and Objectives: Detection of the biomarkers is one of the effective methods for diagnosis and treatment of prostate cancer. Prostate specific antigen (PSA) is currently the best biomarker available for controlling and detecting this cancer. The purpose of the current study was to design an electrochemical aptamer-based biosensor (electrochemical aptasensor) to measure...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry and laboratory medicine
دوره 41 1 شماره
صفحات -
تاریخ انتشار 2003