Measurement of Cardiac Output Using the Photoelectric Earpiece: a Comparison with Simultaneous Fick Measurements.

نویسندگان

  • A O PHINNEY
  • W P CLASON
  • P V STOUGHTON
  • C E MCLEAN
چکیده

• Since the early studies by Hamilton, Werko, and Doyle, and their colleagues, a variety of indicator dilution techniques have been developed for measuring the cardiac output in man. The most widely accepted have been those requiring the use of the continuously recording cuvette densitometer." Numerous studies have appeared to demonstrate close correlation of values by the Hamilton and by the standard Fick methods."

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of relative changes in cardiac output from noncalibrated earpiece dye-dilution curves.

Coomassie Blue dye and the photoelectric earpiece" make it comparatively simple to obtain successive dye-dilution curves without arterial puncture. If the response of the recording system is linear to blood dye concentration and the vascular content of the ear is constant, it should be possible to measure relative changes in cardiac output without calibrating the corves. The purpose of this pap...

متن کامل

Value of Continuous Photoelectric Recording of Dye Curves in the Estimation of Cardiac Output

In order to test photoelectric recording of dye curves, simultaneous determinations of cardiac output were made in 48 patients with heart disease with the Fick and dye-dilution technics. The dye curves were recorded with a Colson densitometer following either intrathoracic or antecubital injection of dye. Both Evans blue and indoeyanine green dyes were employed. Satisfactory agreement was noted...

متن کامل

Simultaneous Measurement of Effective Renal Blood

Unpublished data of Bradley and associates (1) indicate that about 25 to 30 per cent of the cardiac output, as measured by the ballistocardiograph (2), perfuses the kidney of healthy adults at rest. This figure has been reported in a review on renal physiology (3). Levy and Blalock (4) obtained an average value of 18.5 per cent in unanesthetized dogs, using the catheterization technique or hear...

متن کامل

Cardiac output measured by transthoracic impedance cardiography at rest, during exercise and at various lung volumes.

1. Cardiac output measured by transthoracic impedance cardiography has been compared with simultaneous measurements made by the indirect Fick CO2 rebreathing method in nine adults and 14 children. All were healthy normal volunteers. Sixty-six comparisons were made at rest and during steady exercise at work loads up to 100 W. 2. Impedance measurements of cardiac output were consistently higher t...

متن کامل

Automated non-invasive measurement of cardiac output: comparison of electrical bioimpedance and carbon dioxide rebreathing techniques.

Two commercial automated, non-invasive systems for estimation of cardiac output were evaluated. Values of cardiac output obtained by electrical bioimpedance cardiography (BoMed NCCOM3 machine) were compared with values derived from an indirect Fick technique that uses carbon dioxide rebreathing (Gould 9000 IV system) during 103 simultaneous measurements made at rest in 19 randomly selected subj...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 13  شماره 

صفحات  -

تاریخ انتشار 1963