Evaluations of UltraiQ software for objective ultrasound image quality assessment using images from a commercial scanner
نویسندگان
چکیده
We evaluated a commercially available software package that uses B-mode images to semi-automatically measure quantitative metrics of ultrasound image quality, such as contrast response, depth of penetration (DOP), and spatial resolution (lateral, axial, and elevational). Since measurement of elevational resolution is not a part of the software package, we achieved it by acquiring phantom images with transducers tilted at 45 degrees relative to the phantom. Each measurement was assessed in terms of measurement stability, sensitivity, repeatability, and semi-automated measurement success rate. All assessments were performed on a GE Logiq E9 ultrasound system with linear (9L or 11L), curved (C1-5), and sector (S1-5) transducers, using a CIRS model 040GSE phantom. In stability tests, the measurements of contrast, DOP, and spatial resolution remained within a ±10% variation threshold in 90%, 100%, and 69% of cases, respectively. In sensitivity tests, contrast, DOP, and spatial resolution measurements followed the expected behavior in 100%, 100%, and 72% of cases, respectively. In repeatability testing, intra- and inter-individual coefficients of variations were equal to or less than 3.2%, 1.3%, and 4.4% for contrast, DOP, and spatial resolution (lateral and axial), respectively. The coefficients of variation corresponding to the elevational resolution test were all within 9.5%. Overall, in our assessment, the evaluated package performed well for objective and quantitative assessment of the above-mentioned image qualities under well-controlled acquisition conditions. We are finding it to be useful for various clinical ultrasound applications including performance comparison between scanners from different vendors.
منابع مشابه
ایجاد تصویر سه بعدی با استفاده از سیستم های فراصوت دو بعدی معمولی
Ultrasound imaging is one of the common methods in medical diagnostic systems. There are many artifacts in a two dimentional image. Three dimentional imaging can be used for better interpretation and perception of an image. Since 1969 many attemps have been made in this regards, and research continues all over the world. The main goal in...
متن کاملThe perceptibility curve test applied to CCD and two methods of digitization of dental film-based radiographs
Objectives: Several methods of image acquisition are accessible in dentistry. There is no overall acceptable method for image digitization so all different types of images can be comparable. The objective of this study was to compare the diagnostic accuracy of different methods of image digitization. Methods: This accuracy diagnostic test study used perceptibility curve test which first intr...
متن کامل[Comparison of (18)F-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography image quality between commercial and in-house supply of FDG radiopharmaceuticals].
OBJECTIVE PET images are affected by scanner model, reconstruction conditions, injected dose, scan duration, patient health status and FDG radiopharmaceutical supply systems. The present study compares images of 40 patients using commercial and in-house FDG systems with one PET scanner (Aquiduo). METHODS The PET images were evaluated using the physical indexes of NECpatient, NECdensity and SN...
متن کاملQuantitative Comparison of SPM, FSL, and Brainsuite for Brain MR Image Segmentation
Background: Accurate brain tissue segmentation from magnetic resonance (MR) images is an important step in analysis of cerebral images. There are software packages which are used for brain segmentation. These packages usually contain a set of skull stripping, intensity non-uniformity (bias) correction and segmentation routines. Thus, assessment of the quality of the segmented gray matter (GM), ...
متن کاملEvaluation of the quality of CT-like images obtained using a commercial flat panel detector system
PURPOSE The development of flat panel detector technology has resulted in renewed interest in the possibility of generating CT-like images from rotational angiographic acquisitions. At least two commercial products now use cone beam reconstruction software in conjunction with flat panel detectors to produce such images. The purpose of the work presented here is to report on image quality obtain...
متن کامل