Sensitive, specific radioimmunoassay for quantifying pergolide in plasma.
نویسندگان
چکیده
Pergolide, a synthetic ergoline with potent dopaminergic activity, is used to treat Parkinson disease. The low plasma concentrations of pergolide achieved during therapy complicate the development of a method for its analysis. Because radioimmunoassay successfully measures other structurally related ergolines in physiological fluids, we undertook the development of a radioimmunoassay of pergolide. The detection limit of the radioimmunoassay is 21 ng/L with an optimal working range from 100 to 1000 ng/L. We maximized assay specificity by using a monoclonal antibody that displayed low cross-reactivity with pergolide sulfoxide, a major metabolite found in animals. The radioimmunoassay has performed acceptably for > 2 years during toxicology studies with rats and rhesus monkeys and in clinical studies involving patients with Parkinson disease. We consider the radioimmunoassay a valid method for quantifying therapeutic concentrations of pergolide in plasma.
منابع مشابه
DEVELOPMENT OF A RAPID AND SENSITIVE RADIOIMMUNOASSAY FOR MEASUREMENT OF AFLATOXIN B 1 IN BIOLOGICAL SAMPLES
Aflatoxin B I (AFB) isa well known hepatocarcinogen in several animal species and probably a causative agent in human hepatocellular carcinoma. Humans are exposed to AFB by ingesting contaminated food. Aflatoxin contamination encountered in human foods is usually at low levels which is difficult to measure by chromatographic methods. Therefore in the present study we have developed an immun...
متن کاملImproved HPLC-radioimmunoassay for quantifying angiotensin II in plasma.
To measure the octapeptide angiotensin II (Ang II) in plasma, we developed a sensitive, specific assay that interfaces solid-phase extraction, HPLC, and RIA. A reversed-phase HPLC system involving isocratic elution at 38 degrees C with a volatile mobile phase of acetonitrile and the ion-pairing reagent heptafluorobutyric acid produced baseline separation of angiotensin peptides. Ang II was coll...
متن کاملA SPECIFIC, SENSITIVE, AND ONE-STEP EXTRACTION RADIOIMMUNOASSAY OF TESTOSTERONE FOR CLINICAL DIAGNOSIS
Testosterone was measured using antibodies raised against testosterone II B-carboxymethyl ether bovine serum albmin (T-IIB-CME-BSA) and testosterone 3- O-carboxymethyl oxime-BSA as immunogen. The antibody produced in this study exhibits minimal cross reactivity with the structurally related steroids specially 5 dihydrotestosterone (5 DHD. This allows to ommit the clean up step and measure ...
متن کاملComparison of Vitex agnus castus Extract and Pergolide in Treatment of Equine Cushing's Syndrome
Pituitary pars intermedia hyperplasia, which causes Equine Cushing’s Syndrome, has been treated with dopaminergic agonists such as pergolide. Vitex agnus castus (Chaste Berry) extract has been used medicinally for centuries for various human female cycle disorders, and a lay article claimed its therapeutic efficacy in horses with pituitary hyperplasia and other hormonal dysfunction. Ethanol ext...
متن کاملDEVELOPMENT OF A SIMPLE AND SENSITIVE ENZYME- LINKED IMMUNOSORBENT ASSAY (ELISA) FOR CLINICAL MEASUREMENT OF TESTOSTERONE USING PENICILLINASE AS LABEL
An enzyme-linked immunosorbent assay using a homologous combination of antiserum raised against testosterone-3-0-carboxymethyloxime-bovine serum albumin (T-3-0-CMO-BSA ) and penicillinase-labelled T-3-0-CMO was developed. This assay was utilized to measure testosterone in serum samples of male and female subjects. The sensitivity of the assay is 50pg/well and the antibody developed crossrea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 38 10 شماره
صفحات -
تاریخ انتشار 1992