Application of linear model of sorption dynamics to the comparison of solid phase extraction systems of phenol

نویسندگان

  • G. I. Tsysin
  • I. A. Kovalev
  • P. N. Nesterenko
  • N. A. Penner
  • O. A. Filippov
چکیده

A method based on the linear model of sorption dynamics (LMSD) is applied for the comparison of several solid phase extraction systems used for preconcentration of phenol from water solutions. The method includes the calculation of maximum concentration efficiency for the given values of preconcentration factor and recovery under scope of the model. Original parameters of LMSD were obtained from the experimental data on kinetics of sorption of phenol on different hydrophobic non-polar sorbents including poly(styrene-divinylbenzene) (Amberlite XAD-2, PLPRS 100), hypercrosslinked polystyrene (Purosorb MN-200), hexadecylsilica (KSK-G C16) and others (Amberlite XAD-4, Amberchrom CG-161). The suitability of LMSD for evaluation of dynamic sorption systems is discussed. # 2002 Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preconcentration and Determination of Mefenamic Acid in Pharmaceutical and Biological Fluid Samples by Polymer-grafted Silica Gel Solid-phase Extraction Following High Performance Liquid Chromatography

Abstract Mefenamic acid is a nonsteroidal anti-inflammatory drug (NSAID) that has analgesic,anti-infammatory and antipyretic actions. It is used to relieve mild to moderate pains. Solid-phase extraction of mefenamic acid by a polymer grafted to silica gel is reported . Poly allyl glycidyl ether/iminodiacetic acid-co-N, N-dimethylacrylamide was synthesized and grafted to silica gel and was used ...

متن کامل

Preconcentration and Determination of Mefenamic Acid in Pharmaceutical and Biological Fluid Samples by Polymer-grafted Silica Gel Solid-phase Extraction Following High Performance Liquid Chromatography

Abstract Mefenamic acid is a nonsteroidal anti-inflammatory drug (NSAID) that has analgesic,anti-infammatory and antipyretic actions. It is used to relieve mild to moderate pains. Solid-phase extraction of mefenamic acid by a polymer grafted to silica gel is reported . Poly allyl glycidyl ether/iminodiacetic acid-co-N, N-dimethylacrylamide was synthesized and grafted to silica gel and was used ...

متن کامل

Comparison of Modified Palladium Nanoparticles and Homemade Activated Carbon Derived from Medlar for Solid Phase Extraction of Metal Ions Prior to Their Flame Atomic Absorption Spectrometry Determination

This study focus on the preparation of two supports including activated carbon derived from medlar and Palladium nanoparticles loaded on activated carbon (Pd-NP-AC). Subsequently, both adsorbent modified with a novel Schiff base chelating agent and their potential applicability for determination of trace amounts of metal ions from aqueous solution has been investigated. The method is based on c...

متن کامل

Chemically Modified Eggshell Membrane as an Adsorbent for Solid-Phase-Extraction of Morphine Followed by High Performance Liquid Chromatography Analysis

In this project, eggshell membrane was used as a solid phase extraction sorbent for extraction of morphine followed by HPLC analysis. At first, raw eggshell membrane was used and then, because of low adsorption of morphine on untreated eggshell membrane (<70%), modification of eggshell membrane surface was carried out using different surfactants and amines. The amine modified eggshells characte...

متن کامل

Magnetic Solid Phase Extraction and Removal of Five Cationic Dyes from Aqueous Solution Using Magnetite Nanoparticle Loaded Platanusorientalis Waste Leaves

This paper reports on synthesis of a magnetic adsorbent for wastewater treatment purposes. In this regard, platanus orientalis waste leaves were chosen as a cheap material for preparing the magnetic adsorbent by loading magnetite nanoparticles on it. The synthesized adsorbent was characterized using scanning electron microscope and X-ray diffractometer. Then, it was used for magnetic solid phas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003