Frequency of seeing characteristics of the short wavelength sensitive visual pathway in clinically normal subjects and diabetic patients with focal sensitivity loss.
نویسندگان
چکیده
AIMS To define the frequency of seeing (FOS) characteristics of the short wavelength (SW) sensitive visual pathway in clinically normal subjects and in diabetic patients with focal SW sensitivity loss. METHODS For clinically normal subjects, FOS was assessed at two retinal locations (4.24 degrees and 9.90 degrees eccentricity) for both white on white (WW) and SW stimulus parameters. Inter-examination variability was quantified for the clinically normal subjects only. For patients with diabetes, FOS was assessed inside an area of focal SW sensitivity loss, and at the same eccentricity in the quadrant diametrically opposite, using SW stimulus parameters only. RESULTS For clinically normal subjects, the group mean SW FOS slope was significantly flatter (p<0.0001) than that of WW at both locations. The coefficient of repeatability for SW FOS slope was+/-41.55 dB(-1) (relative to a group mean sensitivity of 23.98 dB(-1)) and+/-19.98 dB(-1) (group mean sensitivity 16.15 dB(-1)) for 4.24 degrees and 9.90 degrees , respectively. For the patients with diabetes, the group mean SW FOS slope was significantly flatter (p=0.020), and group mean SW threshold significantly higher (p=0.007) in the area of focal SW sensitivity loss than in that of the non-focal sensitivity loss. CONCLUSIONS The results of this study suggest that the clinical utility of SW automated perimetry will be limited by a greater magnitude of measurement variability, as indicated by a flatter FOS slope, compared to conventional automated perimetry.
منابع مشابه
The statistical interpretation of blue-on-yellow visual field loss.
PURPOSE To evaluate short-wavelength-sensitive perimetry in the detection of glaucomatous field loss. METHODS The sample consisted of 27 normal subjects, 24 patients with primary open angle glaucoma (POAG), and 27 patients with ocular hypertension (OHT). Blue-on-yellow (B-Y) and standard (W-W) perimetry was undertaken with a modified Humphrey Field Analyzer 640 on one eye of each subject and ...
متن کاملQuantification of Visual Field Loss in Age-Related Macular Degeneration
BACKGROUND An evaluation of standard automated perimetry (SAP) and short wavelength automated perimetry (SWAP) for the central 10-2 visual field test procedure in patients with age-related macular degeneration (AMD) is presented in order to determine methods of quantifying the central sensitivity loss in patients at various stages of AMD. METHODS 10-2 SAP and SWAP Humphrey visual fields and s...
متن کاملBlue on yellow perimetry with scanning laser ophthalmoscopy in patients with age related macular disease.
BACKGROUND/AIM The loss of short wavelength sensitive (SWS) cone mechanism sensitivity is related to severe vision loss in patients with age related maculopathy (ARM). A case-control study of patients with ARM and age matched controls was performed, using blue on yellow static perimetry. METHODS A bright yellow background at 594 nm isolated the responses of short wavelength cone mechanisms to...
متن کاملEXTENDED REPORT Blue on yellow perimetry with scanning laser ophthalmoscopy in patients with age related macular disease
Background/aim: The loss of short wavelength sensitive (SWS) cone mechanism sensitivity is related to severe vision loss in patients with age related maculopathy (ARM). A case-control study of patients with ARM and age matched controls was performed, using blue on yellow static perimetry. Methods: A bright yellow background at 594 nm isolated the responses of short wavelength cone mechanisms to...
متن کاملCentral visual fields for short wavelength sensitive pathways in glaucoma and ocular hypertension.
While conventional clinical visual acuity and kinetic visual fields may be essentially normal in ocular hypertension and early stages of glaucoma, other foveal aspects of vision (eg color, spatial and temporal contrast sensitivity) may be quite abnormal. Specifically, a selective vulnerability of the short wavelength sensitive (SWS) visual pathways in these conditions has previously been noted....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 89 11 شماره
صفحات -
تاریخ انتشار 2005