Finite element comparison of retrograde intramedullary nailing and locking plate fixation with/without an intramedullary allograft for distal femur fracture following total knee arthroplasty.

نویسندگان

  • Shih-Hao Chen
  • Ming-Chieh Chiang
  • Ching-Hua Hung
  • Shang-Chih Lin
  • Hsiao-Wei Chang
چکیده

PURPOSE Periprosthetic distal femur fracture after total knee arthroplasty due to the stress-shielding phenomenon is a challenging problem. Retrograde intramedullary nail (RIMN) or locking plate (LP) fixation with/without a strut allograft has been clinically used via less invasive stabilization surgery (LISS) for the treatment of these periprosthetic fractures. However, their biomechanical differences in construct stability and implant stress have not been extensively studied, especially for the osteoporotic femur. METHODS This study used a finite-element method to evaluate the differences between RIMN, LP, and LP/allograft fixation in treating periprosthetic distal femur fractures. There were sixteen variations of two fracture angles (transverse and oblique), two loading conditions (compression and rotation), and four bony conditions (one normal and three osteoporotic). Construct stiffness, fracture micromotion, and implant stress were chosen as the comparison indices. RESULTS The LP/allograft construct provides both lateral and middle supports to the displaced femur. Comparatively, the LP and RIMN constructs, respectively, transmit the loads through the lateral and middle paths, thus providing more unstable support to the construct and high stressing on the implants. The fracture pattern plays a minor role in the construct stabilization of the three implants. In general, the biomechanical performances of the RIMN and LP constructs were comparable and significantly inferior to those of the LP/allograft construct. The bone quality should be evaluated prior to the selection of internal fixators. CONCLUSIONS The LP/allograft construct significantly stabilizes the fracture gap, reduces the implant stress, and serves as the recommended fixation for periprosthetic distal femur fracture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intramedullary nailing versus locked plate for treating supracondylar periprosthetic femur fractures.

The objective of this study was to compare retrograde intramedullary femoral nailing with supracondylar locked screw-plate fixation for the treatment of periprosthetic femur fractures following total knee arthroplasty. Time to union and full weight bearing were the primary study outcomes, with perioperative blood loss, need for transfusion, need for revision surgery, and infection being the sec...

متن کامل

Retrograde Intramedullary Nailing for Periprosthetic Supracondylar Fractures of the Femur after Total Knee Arthroplasty

BACKGROUND Periprosthetic supracondylar fractures of the femur after total knee arthroplasty are not common but are usually difficult to treat due to the advanced age of patients and frequently accompanying osteoporosis. Retrograde intramedullary nailing can be effective in promoting healing of these fractures by providing sufficient stability, but the number of beneficiaries is small due to it...

متن کامل

Stabilization of distal femur fractures with intramedullary nails and locking plates: differences in callus formation.

OBJECTIVES This study compared callus formation in distal femur fractures stabilized with locking plates and intramedullary nails to test the hypothesis that locking plates induce less fracture callus than IM nails. DESIGN Retrospective case matched study. SETTING Two orthopaedic trauma centers. PATIENTS 174 distal femur fracture were reviewed to extract cases treated with retrograde IM n...

متن کامل

Retrograde intramedullary nailing for the treatment of femoral medial condyle fracture nonunion

An unicondylar fracture of the femur is uncommon and of the medial condyle more so. Open reduction and internal fixation of these fractures is most commonly performed with screws or plate and screws. Secure bone fixation is compromised by osteoporosis in elderly patients; additional measures may be required. We report the case of an elderly osteoporotic patient with a medial condyle fracture no...

متن کامل

Blocking screws for the treatment of distal femur fractures.

Intramedullary nailing is one of the most convenient biological options for treating distal femoral fractures. Because the distal medulla of the femur is wider than the middle diaphysis and intramedullary nails cannot completely fill the intramedullary canal, intramedullary nailing of distal femoral fractures can be difficult when trying to obtain adequate reduction. Some different methods exis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Knee

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 2014