Continuous jugular venous oximetry in the neurointensive care unit--a brief review.
نویسندگان
چکیده
PURPOSE To describe the technique of continuous jugular venous oxygen saturation (SjVO(2)) monitoring and review its applications in the neurointensive care unit (NICU), with special reference to the management of raised intracranial pressure (ICP) following severe acute brain injury. SOURCE This narrative review is based on a selection of current literature on SjVO(2) monitoring in conjunction with local experience using this technique. PRINCIPAL FINDINGS Despite limitations, the use of SjVO(2) monitoring has the potential to impact on patient care in the NICU. The placement of the catheter is relatively simple. Studies have confirmed that abnormalities in cerebral venous oxygen saturation are associated with adverse outcome following traumatic brain injury. There is evidence that SjVO(2) may be a useful adjunct to ICP monitoring of patients with intracranial hypertension. Furthermore, managing cerebral extraction of oxygen in conjunction with cerebral perfusion pressure may result in an improved outcome. Further research in this area is needed. Other indications for SjVO(2) monitoring include subarachnoid hemorrhage, cardiopulmonary bypass and following ischemic stroke. CONCLUSION In the past, the management of severe acute brain injury was targeted at ICP and perfusion pressure with little consideration for the metabolic requirements of the injured brain. SjVO(2) monitoring is another tool the intensivist can use to obtain information about the global oxygen requirements of the injured brain on a continuous basis. Whether this will impact on care in the long term remains to be seen.
منابع مشابه
The value of venous oximetry.
PURPOSE OF REVIEW Maintenance of adequate tissue oxygenation is an important task in intensive care units. In this context, venous oximetry by obtaining mixed venous oxygen saturation or central venous oxygen saturation has been discussed as useful monitoring parameters. This review discusses the physiology and clinical application of these parameters. RECENT FINDINGS No study has so far demo...
متن کاملProlonged central venous desaturation measured by continuous oximetry is associated with adverse outcomes in pediatric cardiac surgery.
BACKGROUND The role of continuous central venous oxygen saturation (ScvO₂) oximetry during pediatric cardiac surgery for predicting adverse outcomes is not known. Using a recently available continuous ScvO₂ oximetry catheter, we examined the association between venous oxygen desaturations and patient outcomes. We hypothesized that central venous oxygen desaturations are associated with adverse ...
متن کاملMalposition of central venous catheter in the jugular venous arch via external jugular vein -a case report-
The central venous cannulation is commonly performed in the operating rooms and intensive care units for various purposes. Although the central venous catheter (CVC) is used in many ways, the malpositioning of the CVC is often associated with serious complications. We report a case of an unexpected malposition of a CVC in the jugular venous arch via external jugular vein.
متن کاملUtility of near-infrared spectroscopy for assessing cerebral oxygen saturation during beach chair position.
(NIRS) and jugular venous bulb oximetry during shoulder surgery in the beach chair position. Their results showed a significant lower jugular venous bulb oxygen saturation during beach chair position in the propofol–remifentanil group compared with the sevoflurane–nitrous oxide group. This difference between the two groups was not found for NIRSmeasured cerebral oxygen saturation, which led the...
متن کاملJugular bulb hemoglobin oxygen saturation is not a standard for comparison with cerebral oximetry in head injury.
To the Editor:-Minassian et al. I studied the correlation between cerebral cortical oxyhemoglobin saturation and jugular bulb oxyhemoglobin saturation in patients with head injury, and concluded that, ‘‘Sco2 assessed by NIRS does not adequately reflect changes in Svjo, in patients with severe head injury.” However, jugular bulb oximetry may not be an appropriate standard of cerebral oxygenation...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Canadian journal of anaesthesia = Journal canadien d'anesthesie
دوره 49 6 شماره
صفحات -
تاریخ انتشار 2002