Selective detection of alkanolamine vapors by ion mobility spectrometry with ketone reagent gases.

نویسندگان

  • T H Gan
  • G Corino
چکیده

The ion mobility (IMS) spectra of the alkanolamines, monoethanolamine (MEA), 3-amino-1-propanol (PRA), 4-amino-1-butanol (BUA), and 5-amino-1-pentanol (PEA) with acetone and 4-heptanone reagent gases have been measured using a hand-held spectrometer. Monomer and dimer peak patterns were observed for all the alkanolamines with acetone reagent gas. Drift times of monomer and dimer ion clusters for each alkanolamine increased linearly in order of size of alkyl group. Ammonia, Freon 22, and F76 diesel vapors, having similar or coincident mobilities, caused severe interference. Replacement of acetone with 4-heptanone reagent gas resulted in good separation by the altering drift times of product ions. The limit of detection was 0.005 ppm having a linear range of 0.005-0.7 ppm, and signal saturation occurred above 0.88 ppm. Detection was reversible, with a response time of 4 min and a slower recovery time of > 60 min, at vapor levels of 0.7 ppm and ambient nozzle and drift-region temperatures. In contrast to acetone chemistry, single-peak patterns were observed for the alkanolamines with the 4-heptanone reagent. Further, drift times unexpectedly remained stagnant with increasing alkyl-group size. From atmospheric pressure chemical ionization (APcI) tandem mass spectral identifications and collision induced studies, dynamic changes in product-ion equilibria in the IMS drift region compensated by differences in collision cross sections were suggested as the governing causes of the unusual mobility effect.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD

Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components s...

متن کامل

Application of Ion Mobility Spectrometry for Determination of Morphine in Human Urine

In this study, a rapid, simple and sensitive ion mobility spectrometry (IMS) method with corona discharge as ionization source was described for the morphine determination in human urine. Morphine was extracted and purified from urine samples using solid phase extraction procedure with C18 column. It can offer the clean extracts which no extra peaks were observed in IMS. Under operating experim...

متن کامل

Quantification of selected volatile organic compounds in human urine by gas chromatography selective reagent ionization time of flight mass spectrometry (GC-SRI-TOF-MS) coupled with head-space solid-phase microextraction (HS-SPME).

Selective reagent ionization time of flight mass spectrometry with NO(+) as the reagent ion (SRI-TOF-MS(NO(+))) in conjunction with gas chromatography (GC) and head-space solid-phase microextraction (HS-SPME) was used to determine selected volatile organic compounds in human urine. A total of 16 volatiles exhibiting high incidence rates were quantified in the urine of 19 healthy volunteers. Amo...

متن کامل

Ion Mobility-Mass Spectrometry: Time-Dispersive Instrumentation

■ CONTENTS Basic Ion Mobility Concepts 1423 Electrostatic and Electrodynamic Fields 1423 Resolving Power 1423 Ion Mobility Techniques 1424 Temporally-Dispersive Ion Mobility 1424 Drift Tube Ion Mobility Spectrometry (DTIMS) 1425 Traveling Wave Ion Mobility Spectrometry (TWIMS) 1426 Overtone Mobility Spectrometry (OMS) 1427 Confinement and Mobility-Selective Release 1428 Trapped Ion Mobility Spe...

متن کامل

Microscale extraction of perchlorate in drinking water with low level detection by electrospray-mass spectrometry.

Improper treatment and disposal of perchlorate can be an environmental hazard in regions where solid rocket motors are used, tested, or stored. The solubility and mobility of perchlorate lends itself to ground water contamination, and some of these sources are used for drinking water. Perchlorate in drinking water has been determined at sub-mug l(-1) levels by extraction of the ion-pair formed ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 72 4  شماره 

صفحات  -

تاریخ انتشار 2000