Is there a difference in the positioning of sliding screws between stable and unstable extracapsular fractures?☆
نویسندگان
چکیده
OBJECTIVE To analyze the tip-apex distance (TAD), cervicodiaphyseal angle and Garden angle in stable and unstable extracapsular fractures of the femur treated with a plate and sliding screw. METHOD Hip radiographs in anteroposterior (AP) and lateral view on 117 patients were evaluated. The fractures were classified as stable or unstable, using the AO classification, and the reduction achieved was assessed in accordance with the following criteria: TAD > 3 cm; Garden alignment index (AP) < 160°; and AP cervicodiaphyseal varus angle < 125°. When two or more criteria were present, the quality of the osteosynthesis was classified as "not ideal". RESULTS The patients with unstable fractures presented AP cervicodiaphyseal angles that were significantly greater (p = 0.05) than in those with stable fractures. The patients with unstable fractures presented lateral cervicodiaphyseal angles that were significantly smaller (p = 0.05) than in those with stable fractures. There were no significant differences in the remainder of the criteria evaluated. CONCLUSION This study did not find any significant differences in the measurements evaluated, except in relation to the cervicodiaphyseal angle. Satisfactory reduction was achieved both for the stable and for the unstable fractures, when we used a plate and sliding screw to treat proximal extracapsular fractures of the femur.
منابع مشابه
Application of Far Cortical Locking Technology in Periprosthetic Femoral Fracture Fixation: A Biomechanical Study.
BACKGROUND Lack of fracture movement could be a potential cause of periprosthetic femoral fracture (PFF) fixation failures. This study aimed to test whether the use of distal far cortical locking screws reduces the overall stiffness of PFF fixations and allows an increase in fracture movement compared to standard locking screws while retaining the overall strength of the PFF fixations. METHOD...
متن کاملORTHOPAEDIC SURGERY To retain or remove the syndesmotic screw: a review of literature
Introduction Syndesmotic positioning screws are frequently placed in unstable ankle fractures. Many facets of adequate placement techniques have been the subject of various studies. Whether or not the syndesmosis screw should be removed prior to weight-bearing is still debated. In this study, the recent literature is reviewed concerning the need for removal of the syndesmotic screw. Materials a...
متن کاملMeasurment of stable Glycosylated Hemoglobin (Hb A1) and Its unstable type (pre- Hb A1c) with the lon- exchange Chromatography in Diabetic patients
SUMMARY: At present, measurment of glycosylated hemoglobin, especially the stable fraction of hemoglobin (HbA1c) is one of the ways to control diabetes because this measurment can demonstrate total glycemia during last 1.2.3 months. Glycosylated hemoglobin is seen in 3 forms: Ala Alb A1c. Among these hemoglobin Alc is quantitively more than other 2 forms and its difference with other hemoglobi...
متن کاملAnalysis of using antirotational device on cephalomedullary nail for proximal femoral fractures☆☆☆
OBJECTIVE To analyze the influence of femoral neck diameter in the positioning of the sliding screw in cefalomedulares nails for treatment of unstable transtrochanteric fractures. METHODS Prospectively throughout 2011, patients with unstable fractures transtrochanteric undergoing osteosynthesis with cephalomedullary nail using antirotacional device. They were evaluated for sex, age and fractu...
متن کاملبررسی میزان موفقیت در جاگذاری 180 پیچ پدیکولار بکاررفته در شکستگیهای ناپایدار ستون فقرات توراکولومبار با استفاده از رادیوگرافی ساده در حین عمل جراحی
Background & Aims: Thuracolumbar Unstable Fractures (T, L.U.F) are common after spine truma. Posterior pedicular fixation is a technique that is use for fixation of these fractures. This study evaluates the accuracy of pedicular screw placement in T, LUF with the assistance of plain radiography in operation rooms. Materials & Methods: This study is a case-control and analytical study. 35 pa...
متن کامل