Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements.
نویسندگان
چکیده
OBJECTIVE The objective of our study was to evaluate repeatability and reproducibility of lung nodule volume measurements using volumetric nodule-sizing software. MATERIALS AND METHODS Fifty nodules, less than 20 mm in diameter, in 29 patients were scanned with 1.25-mm collimation using MDCT (time 1 = T1). During the same session, two additional scans, using identical technique, were obtained through each nodule (T2, T3). Three observers working independently then obtained volumetric measurements using a semiautomated volumetric nodule-sizing software package. Qualitative nodule characterization was also performed. The Bland-Altman method for assessing measurement agreement was used to calculate the 95% limits for agreement for nodule volumes at T1, T2, and T3. RESULTS Automated nodule segmentation was successful in 438 (97%) of 450 measurements. Forty-three nodules were available for final evaluation. Twenty-six nodules had well-defined edges, and 17 had irregular or spiculated margins. Seventeen were freestanding, 16 were juxtapleural, and 10 were juxtavascular in location. Average nodule volume was 345.5 mm(3) (range, 49.3-1,434 mm(3)). The mean interobserver variability (repeatability) was 0.018% (SD = 0.73%), and the SD of the mean for the three contemporaneous scans (reproducibility) was 13.1% (confidence limits, +/- 25.6%). SD and confidence limits narrowed as volumes increased. CONCLUSION Volumetric measurements show minimal interobserver variability (0.018%) but an interscan SEM of 13.1% (confidence limits, +/- 25.6%). Repeatability and reproducibility of volumetric measurements are better than those of linear measurements reported in the literature.
منابع مشابه
Pulmonary nodules: Interscan variability of semiautomated volume measurements with multisection CT-- influence of inspiration level, nodule size, and segmentation performance.
PURPOSE To prospectively assess the precision of semiautomated volume measurements of pulmonary nodules at low-dose multi-detector row computed tomography (CT) and to investigate the influence of nodule size, segmentation algorithm, and inspiration level. MATERIALS AND METHODS This study had institutional review board approval; written informed consent was obtained from all patients. Between ...
متن کاملVolumetric Measurements of Lung Nodules with Multi-Detector Row CT: Effect of Changes in Lung Volume
OBJECTIVE To evaluate how changes in lung volume affect volumetric measurements of lung nodules using a multi-detector row CT. MATERIALS AND METHODS Ten subjects with asthma or chronic bronchitis who had one or more lung nodules were included. For each subject, two sets of CT images were obtained at inspiration and at expiration. A total of 33 nodules (23 nodules > or =3 mm) were identified a...
متن کاملPulmonary nodules detected at lung cancer screening: interobserver variability of semiautomated volume measurements.
PURPOSE To retrospectively determine interobserver variability of semiautomated volume measurements of pulmonary nodules and the potential reasons for variability. MATERIALS AND METHODS The Dutch-Belgian lung cancer screening trial (NELSON) is a lung cancer screening study that includes men between the ages of 50 and 75 years who are current or former heavy smokers. The NELSON project was app...
متن کاملVolumetric Analysis of Non-Calcified Lung Nodules with Thoracic CT: an Updated Review of Related work over the Last 5 Years
Lung nodule volumetry with computed tomography has the potential for more reliable measurements of tumor size and therefore determination of temporal changes in a shorter interval of time. In a 2009 review, Gavrielides et al summarized the findings of studies that had examined the inter-related factors affecting the accuracy and precision of volumetric measurements of lung nodules with CT. In t...
متن کامل[Effects of different reconstruction parameters on CT volumetric measurement of pulmonary nodules].
BACKGROUND AND OBJECTIVE It has been proven that volumetric measurements could detect subtle changes in small pulmonary nodules in serial CT scans, and thus may play an important role in the follow-up of indeterminate pulmonary nodules and in differentiating malignant nodules from benign nodules. The current study aims to evaluate the effects of different reconstruction parameters on the volume...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJR. American journal of roentgenology
دوره 186 4 شماره
صفحات -
تاریخ انتشار 2006