Quantification of wave reflection in the human aorta from pressure alone: a proof of principle.

نویسندگان

  • Berend E Westerhof
  • Ilja Guelen
  • Nico Westerhof
  • John M Karemaker
  • Alberto Avolio
چکیده

Wave reflections affect the proximal aortic pressure and flow waves and play a role in systolic hypertension. A measure of wave reflection, receiving much attention, is the augmentation index (AI), the ratio of the secondary rise in pressure and pulse pressure. AI can be limiting, because it depends not only on the magnitude of wave reflection but also on wave shapes and timing of incident and reflected waves. More accurate measures are obtainable after separation of pressure in its forward (P(f)) and reflected (P(b)) components. However, this calculation requires measurement of aortic flow. We explore the possibility of replacing the unknown flow by a triangular wave, with duration equal to ejection time, and peak flow at the inflection point of pressure (F(tIP)) and, for a second analysis, at 30% of ejection time (F(t30)). Wave form analysis gave forward and backward pressure waves. Reflection magnitude (RM) and reflection index (RI) were defined as RM=P(b)/P(f) and RI=P(b)/(P(f)+P(b)), respectively. Healthy subjects, including interventions such as exercise and Valsalva maneuvers, and patients with ischemic heart disease and failure were analyzed. RMs and RIs using F(tIP) and F(t30) were compared with those using measured flow (F(m)). Pressure and flow were recorded with high fidelity pressure and velocity sensors. Relations are: RM(tIP)=0.82RM(mf)+0.06 (R(2)=0.79; n=24), RM(t30)=0.79RM(mf)+0.08 (R(2)=0.85; n=29) and RI(tIP)=0.89RI(mf)+0.02 (R(2)=0.81; n=24), RI(t30)=0.83RI(mf)+0.05 (R(2)=0.88; n=29). We suggest that wave reflection can be derived from uncalibrated aortic pressure alone, even when no clear inflection point is distinguishable and AI cannot be obtained. Epidemiological studies should establish its clinical value.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of noninvasive methods to assess wave reflection and pulse transit time from the pressure waveform alone.

Accurate quantification of pressure wave reflection requires separation of pressure in forward and backward components to calculate the reflection magnitude as the ratio of the amplitudes backward and forward pressure. To do so, measurement of aortic flow in addition to the pressure wave is mandatory, a limitation that can be overcome by replacing the unknown flow wave by an (uncalibrated) tria...

متن کامل

Wave reflection quantification based on pressure waveforms alone - Methods, comparison, and clinical covariates

Within the last decade the quantification of pulse wave reflections mainly focused on measures of central aortic systolic pressure and its augmentation through reflections based on pulse wave analysis (PWA). A complementary approach is the wave separation analysis (WSA), which quantifies the total amount of arterial wave reflection considering both aortic pulse and flow waves. The aim of this w...

متن کامل

Ultrasonic guided waves reflection from simple dent in pipe for defect rate estimation and parameters determination of axisymmetric wave generation source

In this paper, the reflection of ultrasonic guided waves from simple dent in pipes has been investigated using finite element method and the relationship between reflection coefficient of these waves and deformation rate has been determined. Also, the effect of the parameters of wave generation source on the generated wave field has been investigated using normal modes expansion method. At firs...

متن کامل

Reflection and Transmission of Longitudinal Wave at Micropolar Viscoelastic Solid/Fluid Saturated Incompressible Porous Solid Interface

In this paper, the reflection and refraction of longitudinal wave from a plane surface separating a micropolar viscoelastic solid half space and a fluid saturated incompressible half space is studied. A longitudinal wave (P-wave) impinges obliquely at the interface. Amplitude ratios for various reflected and transmitted waves have been obtained. Then these amplitude ratios have been computed nu...

متن کامل

An Optical Measurement System to Measure Velocity and Provide Shock Wave Pressure Diagrams

This paper introduces an optical measurement system for shock wave characteristics. The system works by mountinga metal plate attached to spring mounts against the shock wavefront. This set is sealed and can plot the shock wave pressure diagram by measuring plate's displacement, radiation and changing the reflection of light during shock wave conflict, and converting these optical data to volta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Hypertension

دوره 48 4  شماره 

صفحات  -

تاریخ انتشار 2006