Refractometer for tracking changes in the refractive index of air near 780 nm.

نویسندگان

  • N Khélifa
  • H Fang
  • J Xu
  • P Juncar
  • M Himbert
چکیده

A new system, consisting of a double-channel Fabry-Perot etalon and laser diodes emitting around 780 nm, is described and proposed for use for measuring air-refractive index. The principle of this refractometer is based on frequency measurements between optical laser sources. It permits quasi-instantaneous measurement with a resolution of better than 10(-9) and uncertainty in the 10(-8) range. Some preliminary results on the stability of this system and the measurements of the refractive index of air with this apparatus are presented. The first measurements of the index of air at 780 nm are, within an experimental uncertainty of the order of 2 x 10(-8), in agreement with the predicted values by the so-called revised Edlén equations. This result is, to the best of our knowledge, the first to extend to the near IR the validity of the revised Edlén equation derived for the wavelength range of 350-650 nm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Refractometer for tracking the changes in the refractive index of air near 780 nm

A new system, consisting of a double channel Fabry Perot etalon and laser diodes emitting around 780 nm is described and proposed to be used for air refractive index measurements. The principle of this refractometer is based on frequency measurements between optical laser sources. It permits quasi-instantaneous measurement with a resolution better than 10 9 − and uncertainty in the 10 8 − range...

متن کامل

Refractive Index Compensation in Over-Determined Interferometric Systems

We present an interferometric technique based on a differential interferometry setup for measurement under atmospheric conditions. The key limiting factor in any interferometric dimensional measurement are fluctuations of the refractive index of air representing a dominating source of uncertainty when evaluated indirectly from the physical parameters of the atmosphere. Our proposal is based on ...

متن کامل

Suppression of Air Refractive Index Variations in High-Resolution Interferometry

The influence of the refractive index of air has proven to be a major problem on the road to improvement of the uncertainty in interferometric displacement measurements. We propose an approach with two counter-measuring interferometers acting as a combination of tracking refractometer and a displacement interferometer referencing the wavelength of the laser source to a mechanical standard made ...

متن کامل

High Sensitivity Refractometer Based on TiO2-Coated Adiabatic Tapered Optical Fiber via ALD Technology

Atomic layer deposition (ALD) technology is introduced to fabricate a high sensitivity refractometer based on an adiabatic tapered optical fiber. Different thicknesses of titanium dioxide (TiO₂) nanofilm were coated around the tapered fiber precisely and uniformly under different deposition cycles. Attributed to the higher refractive index of the TiO₂ nanofilm compared to that of silica, an asy...

متن کامل

High sensitivity SMS fiber structure based refractometer--analysis and experiment.

We have investigated the influence of multimode fiber core (MMFC) diameters and lengths on the sensitivity of an SMS fiber based refractometer. We show that the MMFC diameter has significant influence on the refractive index (RI) sensitivity but the length does not. A refractometer with a lower MMFC diameter has a higher sensitivity. Experimental investigations achieved a maximum sensitivity of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 37 1  شماره 

صفحات  -

تاریخ انتشار 1998