PURPOSE To evaluate the quality of vision and depth of focus induced by controlled amounts of negative spherical aberration in patients implanted bilaterally with light-adjustable intraocular lenses. DESIGN Prospective, nonrandomized clinical trial. METHODS Seventeen patients were implanted and treated with appropriate spatial irradiance light profiles. One eye was set for emmetropia, and the fellow eye received an additional aspheric light treatment to induce controlled amounts of negative spherical aberration. We used a Hartmann-Shack sensor to measure the eye's refraction and aberrations for a 4-mm pupil diameter. Decimal visual acuity (VA) was measured using a micro-display placed at 10 m, 60 cm, 40 cm, and 30 cm. RESULTS Eyes treated with aspheric profiles were divided into 2 groups depending on the final amount of induced negative spherical aberration: low [-0.05, -0.10 μm] and high [-0.13, -0.23 μm]. In both groups, the mean uncorrected decimal VA at 60 cm was over 0.90. In the first group, distance VA was 0.97 ± 0.16, but in the second group it was lower (0.76 ± 0.16). As expected, the VA for nearer distances is higher in the eyes with a larger magnitude of spherical aberration (P value < .01): 0.94 ± 0.10 and 0.73 ± 0.16 at 40 and 30 cm, respectively, in comparison with 0.71 ± 0.15 and 0.50 ± 0.14. Binocular summation with the fellow eye, adjusted for emmetropia, produces an excellent binocular distance VA (>1.10) in both groups. CONCLUSIONS Controlled amounts of negative spherical aberration and defocus can be induced in eyes implanted with adjustable intraocular lenses to enhance near vision.
منابع مشابه
Adaptive optics simulation of intraocular lenses with modified spherical aberration.
PURPOSE Adaptive optics systems can be used to investigate the potential visual benefit associated with correcting ocular wave-front aberration. In this study, adaptive optics techniques were used to evaluate the potential advantages and disadvantages associated with intraocular lenses (IOLs) with modified spherical aberration profiles. METHODS An adaptive optics vision simulator was construc...
متن کاملEvaluation of actual retinal images produced by misaligned aspheric intraocular lenses in a model eye
PURPOSE To examine the effect of misalignment (decentration and tilt) of intraocular lenses (IOLs) on retinal image quality using a water-immersed model eye with corneal spherical aberration adjusted to the values found in normal human eyes (spherical aberration 0.25 μm; pupil diameter 6 mm). METHODS Three types of IOL holders were prepared. The first was without decentration or tilt, the sec...
متن کاملTheoretical comparison of aberration-correcting customized and aspheric intraocular lenses.
PURPOSE To assess the performance and optical limitations of standard, aspheric, and wavefront-customized intraocular lenses (IOLs) using clinically verified pseudophakic eye models. METHODS White light pseudophakic eye models were constructed from physical measurements performed on 46 individual cataract patients and subsequently verified using the clinically measured contrast sensitivity fu...
متن کاملHow Is Extended Depth of Focus Achieved with a Small-aperture Lens?
Life happens on small and grand scales, right in front of us and from afar; most of us want to experience all of it. Since the first bifocal IOLs were developed in the 1980s, scientists and manufacturers have been on a dedicated mission to provide individuals with great vision at all distances after cataract surgery. Following those early bifocal lenses, the development of multifocal lenses pro...
متن کاملOptical quality and depth-of-field of eyes implanted with spherical and aspheric intraocular lenses.
PURPOSE To compare experimental optical performance in eyes implanted with spherical and aspheric intraocular lenses (IOLs). METHODS Corneal, total, and internal aberrations were measured in 19 eyes implanted with spherical (n=9) and aspheric (n=10) IOLs. Corneal aberrations were estimated by virtual ray tracing on corneal elevation maps, and total aberrations were measured using a second-gen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of ophthalmology
دوره 157 1 شماره
صفحات -
تاریخ انتشار 2014