A nanocrystalline Hilbert phase-plate for phase-contrast transmission electron microscopy.

نویسندگان

  • M Dries
  • S Hettler
  • B Gamm
  • E Müller
  • W Send
  • K Müller
  • A Rosenauer
  • D Gerthsen
چکیده

Thin-film-based phase-plates are applied to enhance the contrast of weak-phase objects in transmission electron microscopy. In this work, metal-film-based phase-plates are considered to reduce contamination and electrostatic charging, which up to now limit the application of phase-plates fabricated from amorphous C-films. Their crystalline structure requires a model for the simulation of the effect of crystallinity on the phase-plate properties and the image formation process. The model established in this work is verified by experimental results obtained by the application of a textured nanocrystalline Au-film-based Hilbert phase-plate. Based on the model, it is shown that monocrystalline and textured nanocrystalline phase-plate microstructures of appropriate thickness and crystalline orientation can be a promising approach for phase-contrast transmission electron microscopy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Applicability of thin film phase plates in biological electron microscopy

Presented is an evaluation of phase contrast techniques in transmission electron microscopy. The traditional defocus phase contrast is compared to two recently developed phase plate techniques. One is the Zernike phase contrast transmission electron microscope, the other is the Hilbert differential contrast thransmission electron microscope. The imaging characteristics of each technique are dis...

متن کامل

Phase contrast electron microscopy: development of thin-film phase plates and biological applications

Phase contrast transmission electron microscopy (TEM) based on thin-film phase plates has been developed and applied to biological systems. Currently, development is focused on two techniques that employ two different types of phase plates. The first technique uses a Zernike phase plate, which is made of a uniform amorphous carbon film that completely covers the aperture of an objective lens an...

متن کامل

Improved specimen reconstruction by Hilbert phase contrast tomography.

The low signal-to-noise ratio (SNR) in images of unstained specimens recorded with conventional defocus phase contrast makes it difficult to interpret 3D volumes obtained by electron tomography (ET). The high defocus applied for conventional tilt series generates some phase contrast but leads to an incomplete transfer of object information. For tomography of biological weak-phase objects, optim...

متن کامل

First Demonstration of Phase Contrast Scanning Transmission Electron Microscopy

Biological molecules are composed of light elements and can be considered as phase objects for the electron waves. Therefore, images of their unstained specimens show low contrast in transmission electron microscopy (TEM). Phase contrast TEM (P-TEM) is one of the powerful techniques to enhance image contrast of the phase objects [1]. In P-TEM, the phase plate (PP) is placed at a back focal plan...

متن کامل

Transmission electron microscopy with Zernike phase plate.

The possibility of implementing a Zernike phase plate in a transmission electron microscope is investigated both theoretically and experimentally. The phase-retarding plate in the form of thin film with a hole in the center is positioned in the back-focal plane of the objective lens. The experiments show that the phase plate functions as predicted, producing a cosine-type phase contrast transfe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultramicroscopy

دوره 139  شماره 

صفحات  -

تاریخ انتشار 2014