Amplicon DNA melting analysis for mutation scanning and genotyping: cross-platform comparison of instruments and dyes.

نویسندگان

  • Mark G Herrmann
  • Jacob D Durtschi
  • L Kathryn Bromley
  • Carl T Wittwer
  • Karl V Voelkerding
چکیده

BACKGROUND DNA melting analysis for genotyping and mutation scanning of PCR products by use of high-resolution instruments with special "saturation" dyes has recently been reported. The comparative performance of other instruments and dyes has not been evaluated. METHODS A 110-bp fragment of the beta-globin gene including the sickle cell anemia locus (A17T) was amplified by PCR in the presence of either the saturating DNA dye, LCGreen Plus, or SYBR Green I. Amplicons of 3 different genotypes (wild-type, heterozygous, and homozygous mutants) were melted on 9 different instruments (ABI 7000 and 7900HT, Bio-Rad iCycler, Cepheid SmartCycler, Corbett Rotor-Gene 3000, Idaho Technology HR-1 and LightScanner, and the Roche LightCycler 1.2 and LightCycler 2.0) at a rate of 0.1 degrees C/s or as recommended by the manufacturer. The ability of each instrument/dye combination to genotype by melting temperature (Tm) and to scan for heterozygotes by curve shape was evaluated. RESULTS Resolution varied greatly among instruments with a 15-fold difference in Tm SD (0.018 to 0.274 degrees C) and a 19-fold (LCGreen Plus) or 33-fold (SYBR Green I) difference in the signal-to-noise ratio. These factors limit the ability of most instruments to accurately genotype single-nucleotide polymorphisms by amplicon melting. Plate instruments (96-well) showed the greatest variance with spatial differences across the plates. Either SYBR Green I or LCGreen Plus could be used for genotyping by T(m), but only LCGreen Plus was useful for heterozygote scanning. However, LCGreen Plus could not be used on instruments with an argon laser because of spectral mismatch. All instruments compatible with LCGreen Plus were able to detect heterozygotes by altered melting curve shape. However, instruments specifically designed for high-resolution melting displayed the least variation, suggesting better scanning sensitivity and specificity. CONCLUSION Different instruments and dyes vary widely in their ability to genotype homozygous variants and scan for heterozygotes by whole-amplicon melting analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Expanded instrument comparison of amplicon DNA melting analysis for mutation scanning and genotyping.

BACKGROUND Additional instruments have become available since instruments for DNA melting analysis of PCR products for genotyping and mutation scanning were compared. We assessed the performance of these new instruments for genotyping and scanning for mutations. METHODS A 110-bp fragment of the beta-globin gene including the sickle cell anemia locus (HBB c. 20A>T) was amplified by PCR in the ...

متن کامل

High-resolution genotyping by amplicon melting analysis using LCGreen.

BACKGROUND High-resolution amplicon melting analysis was recently introduced as a closed-tube method for genotyping and mutation scanning (Gundry et al. Clin Chem 2003;49:396-406). The technique required a fluorescently labeled primer and was limited to the detection of mutations residing in the melting domain of the labeled primer. Our aim was to develop a closed-tube system for genotyping and...

متن کامل

Multiplex Fluorescence Melting Curve Analysis for Mutation Detection with Dual-Labeled, Self-Quenched Probes

Probe-based fluorescence melting curve analysis (FMCA) is a powerful tool for mutation detection based on melting temperature generated by thermal denaturation of the probe-target hybrid. Nevertheless, the color multiplexing, probe design, and cross-platform compatibility remain to be limited by using existing probe chemistries. We hereby explored two dual-labeled, self-quenched probes, TaqMan ...

متن کامل

Multiplex amplicon genotyping by high-resolution melting.

High-resolution amplicon melting is a simple method for genotyping that uses only generic PCR primers and a saturating DNA dye. Multiplex amplicon genotyping has previously been reported in a single color, but two instruments were required: a carousel-based rapid cycler and a high-resolution melting instrument for capillaries. Manual transfer of capillaries between instruments and sequential me...

متن کامل

High-resolution DNA melting analysis for simple and efficient molecular diagnostics.

High-resolution melting of DNA is a simple solution for genotyping, mutation scanning and sequence matching. The melting profile of a PCR product depends on its GC content, length, sequence and heterozygosity and is best monitored with saturating dyes that fluoresce in the presence of double-stranded DNA. Genotyping of most variants is possible by the melting temperature of the PCR products, wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 52 3  شماره 

صفحات  -

تاریخ انتشار 2006