New screening system for simultaneous determination of two marker proteins by homogeneous enzyme immunoassay.

نویسندگان

  • N Hoshino
  • K Miyai
چکیده

AIMS To save time and labour in mass screening, by detecting two marker proteins on one specimen using only one test. METHODS alpha Fetoprotein and ferritin were chosen to demonstrate the principal of this system. The assay reagents were horseradish peroxidase (HRP)-labelled anti-alpha fetoprotein and HRP-labelled anti-ferritin antibodies. After the serum sample had been incubated with these reagents the substrate for HRP was added and the absorbance measured. An absorbance value below the cutoff point indicated that both parameters were within normal limits; a value above the cutoff point indicated that at least one of the two parameters was abnormally high. RESULTS Fifty sera from healthy Japanese subjects were assayed by the simultaneous assay method. All samples gave absorbancy values below the cutoff point. Fifty serum samples from patients with high alpha fetoprotein concentrations (over 20 ng/ml) and 50 samples with high ferritin concentrations (over 200 ng/ml) were also assayed. The absorbancy values of all samples with high alpha fetoprotein concentrations, and all but one sample with high ferritin concentrations gave values above the cutoff point. CONCLUSIONS Although this homogeneous enzyme assay method was applied to the combination of alpha fetoprotein and ferritin, it could be used in mass screening for any other combination of two markers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DETERMINATION OF SERUM CORTISOL LEVEL BY A DIREC T ENZYME IMMUNOASSAY USING PENICILLINASE AS LABEL

Serum cortisol level was measured by an enzyme immunoassay (EIA) using the enzyme penicillinase as a label without prior extraction and purification. Polyclonal antibodies were raised against cortisol-3-ortho-carboxymethyl-oxime (cortisol-3-0-CMO) conjugated to bovine serum albumin (BSA). This antibody showed a very low cross-reactivity with structurally related steroids (3.7% for corticos...

متن کامل

Potential liabilities of gentamicin homogeneous enzyme immunoassay.

We report two potential liabilities of the homogeneous enzyme immunoassay for the determination of serum gentamicin. One is a considerable loss of precision and accuracy at the ends of the calibration curve, and the other is an apparent loss of gentamicin with storage at -60 degrees C.

متن کامل

ارزیابی و مقایسه ENZYME IMMUNOASSAY (EIA) و رنگ آمیزی اسید فاست با تایید به روش ایمنو فلورسنت آنتی‌بادی جهت تشخیص گونه‌های کریپتوسپوریدیوم

Introduction: Cryptosporidiosis is prevalent world wide, causing a variety of problems ranging from acute, self-limiting diarrhea to fatal cases in immunocompromised persons, particulary those with acquired immunodeficiency (AIDS). Diagnosis of Cryptosporidium is made by identification of oocysts in stool specimens. The detection is most commonly made by the acid-fast staining method followed b...

متن کامل

Analysis of oxidative stress biomarkers using a simultaneous competitive/non-competitive micromosaic immunoassay.

Immunoassays represent a core workhorse methodology for many applications ranging from clinical diagnostics to environmental monitoring. In traditional formats such as the enzyme linked immunosorbent assay (ELISA), analytes are measured singly or in small sets. As more biomarkers are identified for disease states, there is a need to develop methods that can measure multiple markers simultaneous...

متن کامل

Application of Differential Kinetic Method Using ANN with a New Synthetic Reagent for Simultaneous Spectrophotometric Determination of Mercury and Palladium

A new selective reagent was used for simultaneous determination of mercury and palladium in real samples with their different kinetic spectrophotometric properties. The method is based on the difference in the rate of the oxidation reaction of the recently synthesized reagent, nitro benzoyl diphenylmethylen phosphorane (N-BDMP), with Hg2+ and Pd2+. The kinetic profiles were monitored and record...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 45 3  شماره 

صفحات  -

تاریخ انتشار 1992