Percutaneous closure of multiple secundum atrial septal defects using 3 amplatzer atrial septal occluder devices: evaluation by live transthoracic 3-dimensional echocardiography.
نویسندگان
چکیده
A previously healthy 12-year-old boy was admitted to the hospital with acute pneumonitis. On admission, a heart murmur was detected. The transthoracic echocardiogram showed multiple secundum atrial septal defects with left-toright shunt and signs of right ventricular volume overload. He underwent right cardiac catheterization and transesophageal echocardiogram (transesophageal echocardiography): 3 sizeable atrial septal defects (anterosuperior, measuring 10 mm; posterior, 9 mm; anteroinferior, 6 mm) were closed with 3 Amplatzer atrial septal occluder devices, measuring 10, 9, and 6 mm (Figures 1 and 2). A good result was achieved, with no residual shunt across the atrial septum and no complications. The live transthoracic 3D (Figures 3 and 4, Data Supplement Movies I and II) and concurrent transesophageal echocardiography assessment at the end of the procedure showed good position of the devices, no residual interatrial shunts, no interference with the atrioventricular valves, and no obstruction to the venous returns. To our knowledge, there have been no previous reports of 3D echocardiographic imaging after transcatheter closure of multiple atrial septal defects using 3 devices.1 Few previous reports focus on the initial results of 3D echocardiographic analysis based on image acquisition and offline postprocessing.2,3 Live transthoracic 3D echocardiography was used for the first time to evaluate the postprocedural results, and it proved to be a useful tool to assess the spatial relationship between the devices and with the surrounding structures.
منابع مشابه
Live/Real Time Three-Dimensional Trans Esophageal Echocardiographic Findings in Amplatzer ASD Closure Devices in Adults
Six female patients aged from 19 to 73 years, with ostium secundum atrial septal defect underwent closure procedure with Amplatzer septal occluder device. Three-dimensional Echocardiography (3D-TEE) was done during the procedure or one day after the procedure. 3D-TEE provides incremental value over Two- dimensional trans-esophageal echocardiography in measuring Amplatzer septal occluder disc si...
متن کاملTranscatheter closure of atrial septal defects with transthoracic echocardiography.
OBJECTIVES The aim of this study is to evaluate our clinical experience using an Amplatzer septal occluder for catheter closure of a secundum atrial septal defect under transthoracic echocardiography guidance without general anaesthesia. METHODS Patients eligible for transcatheter atrial septal defect closure were selected using transthoracic echocardiography. The largest defect diameter meas...
متن کاملAssessment of the geometric profile of the Amplatzer and Cardioseal septal occluders by three dimensional echocardiography.
OBJECTIVE To apply three dimensional echocardiography to describe the geometric profile of the Amplatzer and Cardioseal occluders after deployment for closure of atrial septal defect. METHODS 20 patients (mean (SD) age, 14 (5) years) were enrolled for transcatheter closure of a secundum atrial septal defect with the Amplatzer occluder (10) or with the Cardioseal occluder (10). The two populat...
متن کاملTranscatheter closure of multiple atrial septal defects. Initial results and value of two- and three-dimensional transoesophageal echocardiography.
AIMS To examine the feasibility of transcatheter closure of multiple atrial septal defects using two Amplatzer devices simultaneously and to describe the importance and the role of two- and three-dimensional transoesophageal echocardiography in the selection and closure of such defects. METHODS Twenty-two patients with more than one atrial septal defect underwent an attempt at transcatheter c...
متن کاملReal-time three-dimensional transesophageal echocardiography is useful for percutaneous closure of multiple secundum atrial septal defects.
INTRODUCTION The purpose of this study was to investigate the clinical value of real-time three-dimensional transesophageal echocardiography (RT-3D-TEE) for percutaneous transcatheter closure of multiple secundum atrial septal defects (ASDs) using a Chinese domestic occluder device. METHODS From July 2008 to September 2011, 37 patients (mean age 28.4 ± 9.7 years; 24 females) with multiple sec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Cardiovascular imaging
دوره 1 2 شماره
صفحات -
تاریخ انتشار 2008