What is the relationship between the minimally important difference and health state utility values? The case of the SF-6D
نویسندگان
چکیده
BACKGROUND The SF-6D is a new single summary preference-based measure of health derived from the SF-36. Empirical work is required to determine what is the smallest change in SF-6D scores that can be regarded as important and meaningful for health professionals, patients and other stakeholders. OBJECTIVES To use anchor-based methods to determine the minimally important difference (MID) for the SF-6D for various datasets. METHODS All responders to the original SF-36 questionnaire can be assigned an SF-6D score provided the 11 items used in the SF-6D have been completed. The SF-6D can be regarded as a continuous outcome scored on a 0.29 to 1.00 scale, with 1.00 indicating "full health". Anchor-based methods examine the relationship between an health-related quality of life (HRQoL) measure and an independent measure (or anchor) to elucidate the meaning of a particular degree of change. One anchor-based approach uses an estimate of the MID, the difference in the QoL scale corresponding to a self-reported small but important change on a global scale. Patients were followed for a period of time, then asked, using question 2 of the SF-36 as our global rating scale, (which is not part of the SF-6D), if there general health is much better (5), somewhat better (4), stayed the same (3), somewhat worse (2) or much worse (1) compared to the last time they were assessed. We considered patients whose global rating score was 4 or 2 as having experienced some change equivalent to the MID. In patients who reported a worsening of health (global change of 1 or 2) the sign of the change in the SF-6D score was reversed (i.e. multiplied by minus one). The MID was then taken as the mean change on the SF-6D scale of the patients who scored (2 or 4). RESULTS This paper describes the MID for the SF-6D from seven longitudinal studies that had previously used the SF-36. CONCLUSIONS From the seven reviewed studies (with nine patient groups) the MID for the SF-6D ranged from 0.010 to 0.048, with a weighted mean estimate of 0.033 (95% CI: 0.029 to 0.037). The corresponding Standardised Response Means (SRMs) ranged from 0.11 to 0.48, with a mean of 0.30 and were mainly in the "small to moderate" range using Cohen's criteria, supporting the MID results. Using the half-standard deviation (of change) approach the mean effect size was 0.051 (range 0.033 to 0.066). Further empirical work is required to see whether or not this holds true for other patient groups and populations.
منابع مشابه
Utility Estimation of Health Status of Cancer Patients by Mapping for Cost-Utility Analysis
Background: It is important to obtain accurate information about the preferences of people for measuring quality-adjusted life years (QALYs), because it is necessary for cost-utility analysis. In this regard, mapping is a method to access this information. Therefore, the purpose of this study was to map Functional Assessment of Cancer Therapy – General (FACT-G) onto Short Form Six Dimension (SF...
متن کاملEstimation of minimally important differences in the EQ-5D and SF-6D indices and their utility in stroke
BACKGROUND The aim of the present study was to estimate minimally important differences (MIDs) in EQ-5D and SF-6D indices and to explore the responsiveness of EQ-5D and SF-6D indices in stroke. METHODS We used observational longitudinal survey data of EQ-5D and SF-36 that were administered to stroke patients at baseline and at 10 months. A range of MIDs for both indexes was estimated using an...
متن کاملEstimating health state utility values for comorbid health conditions using SF-6D data.
INTRODUCTION When health state utility values for comorbid health conditions are not available, data from cohorts with single conditions are used to estimate scores. The methods used can produce very different results and there is currently no consensus on which is the most appropriate approach. OBJECTIVE The objective of the current study was to compare the accuracy of five different methods...
متن کاملSacroiliac joint pain: burden of disease
OBJECTIVES The sacroiliac joint (SIJ) is an important and significant cause of low back pain. We sought to quantify the burden of disease attributable to the SIJ. METHODS The authors compared EuroQol 5D (EQ-5D) and Short Form (SF)-36-based health state utility values derived from the preoperative evaluation of patients with chronic SIJ pain participating in two prospective clinical trials of ...
متن کاملA Comparison between the EQ-5D and the SF-6D in Patients with Chronic Obstructive Pulmonary Disease (COPD)
BACKGROUND The appropriate use of generic preference-based measures determines the accuracy of disease assessment and further decision on healthcare policy using quality adjusted life years. The discriminative capacity of different instruments would differ across disease groups. Our study was to examine the difference in utility scores for COPD patients measured by EQ-5D and SF-6D and to assist...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Health and Quality of Life Outcomes
دوره 1 شماره
صفحات -
تاریخ انتشار 2003