Ventilation/perfusion mismatch during lung aeration at birth.

نویسندگان

  • Justin A R Lang
  • James T Pearson
  • Arjan B te Pas
  • Megan J Wallace
  • Melissa L Siew
  • Marcus J Kitchen
  • Andreas Fouras
  • Robert A Lewis
  • Kevin I Wheeler
  • Graeme R Polglase
  • Mikiyasu Shirai
  • Takashi Sonobe
  • Stuart B Hooper
چکیده

At birth, the transition to newborn life is triggered by lung aeration, which stimulates a large increase in pulmonary blood flow (PBF). Current theories predict that the increase in PBF is spatially related to ventilated lung regions as they aerate after birth. Using simultaneous phase-contrast X-ray imaging and angiography we investigated the spatial relationships between lung aeration and the increase in PBF after birth. Six near-term (30-day gestation) rabbits were delivered by caesarean section, intubated and an intravenous catheter inserted, before they were positioned for X-ray imaging. During imaging, iodine was injected before ventilation onset, after ventilation of the right lung only, and after ventilation of both lungs. Unilateral ventilation increased iodine levels entering both left and right pulmonary arteries (PAs) and significantly increased heart rate, iodine ejection per beat, diameters of both left and right PAs, and number of visible vessels in both lungs. Within the 6th intercostal space, the mean gray level (relative measure of iodine level) increased from 68.3 ± 11.6 and 70.3 ± 7.5%·s to 136.3 ± 22.6 and 136.3 ± 23.7%·s in the left and right PAs, respectively. No differences were observed between vessels in the left and right lungs, despite the left lung not initially being ventilated. The increase in PBF at birth is not spatially related to lung aeration allowing a large ventilation/perfusion mismatch, or pulmonary shunting, to occur in the partially aerated lung at birth.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of surfactant depletion on regional pulmonary metabolic activity during mechanical ventilation.

Inflammation during mechanical ventilation is thought to depend on regional mechanical stress. This can be produced by concentration of stresses and cyclic recruitment in low-aeration dependent lung. Positron emission tomography (PET) with (18)F-fluorodeoxyglucose ((18)F-FDG) allows for noninvasive assessment of regional metabolic activity, an index of neutrophilic inflammation. We tested the h...

متن کامل

Lung [(18)F]fluorodeoxyglucose uptake and ventilation-perfusion mismatch in the early stage of experimental acute smoke inhalation.

BACKGROUND Acute lung injury occurs in a third of patients with smoke inhalation injury. Its clinical manifestations usually do not appear until 48-72 h after inhalation. Identifying inflammatory changes that occur in pulmonary parenchyma earlier than that could provide insight into the pathogenesis of smoke-induced acute lung injury. Furthermore, noninvasive measurement of such changes might l...

متن کامل

Monitoring Lung Aeration during Respiratory Support in Preterm Infants at Birth

BACKGROUND If infants fail to initiate spontaneous breathing, resuscitation guidelines recommend respiratory support with positive pressure ventilation (PPV). The purpose of PPV is to establish functional residual capacity and deliver an adequate tidal volume (VT) to achieve gas exchange. OBJECTIVE The aim of our pilot study was to measure changes in exhaled carbon dioxide (ECO2), VT, and rat...

متن کامل

Regional distribution of lung perfusion and ventilation at rest and during steady-state exercise after unilateral lung transplantation.

Cardiopulmonary exercise testing has previously demonstrated a reduced maximum oxygen uptake and anaerobic threshold, as well as abnormal wasted ventilation fraction and gas exchange after unilateral lung transplantation. To further explain the mechanisms of these abnormalities, we assessed the regional distribution of pulmonary blood flow and ventilation at rest and during steady-state exercis...

متن کامل

Electrical impedance tomography applied to assess matching of pulmonary ventilation and perfusion in a porcine experimental model

INTRODUCTION Electrical impedance tomography (EIT) can be used to measure impedance changes related to the thoracic content of air and blood. Few studies, however, have utilised EIT to make concurrent measurements of ventilation and perfusion. This experimental study was performed to investigate the feasibility of EIT to describe ventilation/perfusion (V/Q) matching after acute changes of pulmo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 117 5  شماره 

صفحات  -

تاریخ انتشار 2014