Erratum: Flow Cytometric White Blood Cell Differential Using CytoDiff is Excellent for Counting Blasts

نویسندگان

  • Jimin Kahng
  • Yonggoo Kim
  • Myungshin Kim
  • Eun-Jee Oh
  • Yeon-Joon Park
  • Kyungja Han
چکیده

BACKGROUND The usefulness of the CytoDiff flow cytometric system (Beckman Coulter, USA) has been studied in various conditions, but its performance including rapidity in detecting and counting blasts, the most significant abnormal cells in the peripheral blood, has not been well evaluated. The objective of this study was to evaluate the performance of the CytoDiff differential counting method in challenging samples with blasts. METHODS In total, 815 blood samples were analyzed. Samples flagged as "blasts" or "variant lymphocytes" and showing <10% blasts by manual counts were included. In total, 322 samples showed blasts on manual counts, ranging from 0.5% to 99%. The CytoDiff method was performed by flow cytometry (FC500; Beckman Coulter, USA) with a pre-mixed CytoDiff reagent and analyzing software (CytoDiff CXP 2.0; Beckman Coulter). RESULTS The average time required to analyze 20 samples was approximately 60 min for manual counts, and the hands-on time for the CytoDiff method was 15 min. The correlation between the CytoDiff and manual counts was good (r>0.8) for neutrophils and lymphocytes but poor (r<0.8) for other cells. When the cutoff value of the CytoDiff blast count was set at 1%, the sensitivity was 94.4% (95% CI; 91.2-96.6) and specificity was 91.9% (95% CI; 89.0-94.1). The positive predictive value was 88.4% (95% CI; 84.4-91.5) (304/344 cases) and negative predictive value was 96.2% (95% CI; 93.9-97.7) (453/471 cases). The CytoDiff blast counts correlated well to the manual counts (r=0.9223). CONCLUSIONS The CytoDiff method is a specific, sensitive, and rapid method for counting blasts. A cutoff value of 1% of at least 1 type of blast is recommended for positive CytoDiff blast counts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliable, Accurate Determination of the Leukocyte Differential of Leukopenic Samples by Using Hematoflow Method

BACKGROUND Hematology analyzers may ineffectively recognize abnormal cells, and manual differential counts may be imprecise for leukopenic samples. We evaluated the efficacy of the Hematoflow method for determining the leukocyte differential in leukopenic samples and compared this method with the manual differential method. METHODS We selected 249 blood samples from 167 patients with leukopen...

متن کامل

White blood cell differential counts in severely leukopenic samples: a comparative analysis of different solutions available in modern laboratory hematology

BACKGROUND We evaluated the efficacy of white blood cell (WBC) differential counts in severely leukopenic samples by the Hematoflow method and by automated hematology analyzers and compared the results with manual counts. METHODS EDTA-anticoagulated blood samples (175 samples) with WBC counts of 40-990/µL were selected. Hematoflow differential counts were performed in duplicates employing flo...

متن کامل

Use of Four-Color Flow Cytometric Assay for Discrimination of Hematogone from Lymphoblast: Critical Issue for MRD Assessment in B-ALL Patients

Background: Hematogones are normal B-cell precursor which can be seen in different physiological and pathological conditions. Due to variation in B-cell acute lymphoblastic leukemia (B-ALL) blasts immunophenotyping and interference of hematogones in minimal residual disease (MRD) assessment, precise discrimination of hematogones is very crucial.  The purpose of this study was to evaluate the ex...

متن کامل

Leukoflow: multiparameter extended white blood cell differentiation for routine analysis by flow cytometry.

Differential white blood cell count (dWBC) is a frequently used diagnostic tool. For most patient samples an automated blood counter produces a five-part differential count. If this dWBC does not meet pre-set criteria, microscopic dWBC is performed. Microscopy is labor intensive and requires sustained training of technicians. Inter-observer variation and statistical variation are significant, d...

متن کامل

Validity of Selected WBC Differentiation Flags in Sysmex XT-1800i

Background: Automatic Cell Counter devises make the CBC differential very easy and delivering the results in few second. However, the problem with this device is facing a flag requires a time-consuming microscopic review of the specimen which causes unacceptable wait times for patient as well as costs for laboratories. In this study, we calculated the validity of WBC d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 35  شماره 

صفحات  -

تاریخ انتشار 2015