Electrogenerated chemiluminescence. 58. Ligand-sensitized electrogenerated chemiluminescence in europium labels.

نویسندگان

  • M M Richter
  • A J Bard
چکیده

The electrochemistry and electrogenerated chemiluminescence (ECL) of a series of europium chelates, cryptates, and mixed-ligand chelate/cryptand complexes were studied. The complexes were of the following general forms:  EuL(4)(-), where L = β-diketonate, a bis-chelating ligand (such as dibenzoylmethide), added as salts (A)EuL(4), where A = tetrabutylammonium ion or piperidinium ion (pipH(+)); Eu(crypt)(3+), where crypt = a cryptand ligand, e.g., 4,7,13,16,21-pentaoxa-1,10-diazabicyclo[8,8,5]tricosane; and Eu(crypt)(L)(2+) for the mixed-ligand systems. ECL was obtained for the chelates and mixed-ligand systems by reducing the complexes at a Pt electrode in the presence of peroxydisulfate in acetonitrile solutions and was attributed to the electron-transfer reaction between the reduced bound ligands and SO(4)(•)(-), followed by intramolecular excitation transfer from the excited ligand orbitals to the metal-centered 4f states. No ECL was observed under the same conditions for the europium complexes incorporating only the cryptand ligands in aqueous solution. The ECL spectra matched the photoluminescence spectra with a narrow emission band observed at 612 nm, corresponding to a metal-centered 4f-4f transition. The ECL efficiencies for the ECL-active species were low, about 10(-)(1)-10(-)(4)% of that of the Ru(bpy)(3)(2+)/S(2)O(8)(2)(-) system under similar conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrochemistry and electrogenerated chemiluminescence of organic nanoparticles

This review discusses briefly the preparation, electrochemistry, and electrogenerated chemiluminescence (ECL) as well as spectroscopic properties of organic nanoparticles. Organic nanoparticles, ranging from several tens of nanometers to hundreds of nanometers in diameter, were successfully prepared by various methods. Using a simple reprecipitation method, organic nanoparticles of a very small...

متن کامل

Developments and Applications of Electrogenerated Chemiluminescence Sensors Based on Micro- and Nanomaterials

A variety of recent developments and applications of electrogenerated chemiluminescence (ECL) for sensors are described. While tris(2,2'-bipyridyl)-ruthenium(II) and luminol have dominated and continue to pervade the field of ECL-based sensors, recent work has focused on use of these lumophores with micro- and nanomaterials. It has also extended to inherently luminescent nanomaterials, such as ...

متن کامل

Electrogenerated chemiluminescence Part 54. Electrogenerated chemiluminescence of ruthenium( II) 4,4’-diphenyl-2,2’-bipyridine and ruthenium( II) 4,7-diphenyl-l,lO-phenanthroline systems in aqueous and acetonitrile solutions

The electrogenerated chemiluminescence (ECL) of Ru(dp-bpy):+ (dp-bpy = 4,4’-diphenyl-2,2’bipyridine) and Ru(dp-phen):+ (dp-phen = 4,7-diphenyl-l,lO-phenanthroline) in acetonitrile and aqueous solutions was studied. The diphenyl-substituted compounds produced a more intense emission than the nonsubstituted Ru(bpy):+ Ru(dp-phen):+ m acetonitrile. The ECL efficiencies, dECL, of Ru(dp-bpy):+ and we...

متن کامل

Electrogenerated chemiluminescence from Au nanoclusters.

Electrogenerated chemiluminescence (ECL) of Au clusters is observed for the first time using triethyamine (TEA) as the coreactant. The potential application of ECL Au clusters in analytical chemistry is also demonstrated using Pb(2+) as an example.

متن کامل

Electrogenerated chemiluminescence . 41 . Electrogenerated chemiluminescence and chemiluminescence of the Ru ( 2 , 2 1 - bpy ) 32 + - S 2 O 82 - system in acetonitrile - water solutions

The electrogenerated chemiluminescence (ecl) produced in acetonitrile-water solutions (1: 1 by volume) by the reaction of electrogenerated Ru(bpy),+ with the strongly oxidizing intermediate, SO4--, generated during reduction of S208” is described. The orange luminescence (A, = 625 nm) corresponds to emission from R~(bpy) ,~+*. The relative ecl intensity is a function of S20s2concentration, and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 68 15  شماره 

صفحات  -

تاریخ انتشار 1996