A new spectroelectrochemical cell to investigate the structure of Pt/Au nanoclusters using Pt and Au K-edge X-ray absorption fine structure (XAFS) measurements under the electrochemical conditions is developed. K-edge XAFS measurements for Pt and Au require a sample as thick as 1-2 cm, which prevents homogeneous potential distribution. We can measure in situ Pt and Au K-edge XAFS spectra and determine reasonable electrochemical surface areas using our developed spectroelectrochemical cell. This work provides a new approach to analyze Pt/Au core-shell nanoclusters. The new cell is designed to be applied to both spectra with high absorption-edge energies such as the K-edge of Pt and Au and those with low absorption-edge energy such as Pt L-edge.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electronic and magnetic properties of ultrathin Au/Pt nanowires.

We have reported the synthesis of Au(25)Pt(75) and Au(48)Pt(52) alloyed ultrathin nanowires with average widths of less than 3 nm via a wet chemistry approach at room temperature. Using a combination of techniques, including scanning transmission electron microscopy equipped with X-ray energy dispersive spectroscopy, ultraviolet-visible spectroscopy, and X-ray absorption near-edge structure and...

متن کامل

Stabilization of platinum oxygen-reduction electrocatalysts using gold clusters.

We demonstrated that platinum (Pt) oxygen-reduction fuel-cell electrocatalysts can be stabilized against dissolution under potential cycling regimes (a continuing problem in vehicle applications) by modifying Pt nanoparticles with gold (Au) clusters. This behavior was observed under the oxidizing conditions of the O2 reduction reaction and potential cycling between 0.6 and 1.1 volts in over 30,...

متن کامل

A high-temperature in situ cell with a large solid angle for fluorescence X-ray absorption fine structure measurement.

We present the design and performance of a high-temperature in situ cell with a large solid angle for fluorescence X-ray absorption fine structure (XAFS) spectra. The cell has a large fluorescence XAFS window (116 mm(ϕ)) near the sample in the cell, realizing a large half-cone angle of 56°. We use a small heater (25 × 35 mm(2)) to heat the sample locally to 873 K. We measured a Pt-SnO2 thin lay...

متن کامل

Evaluation of X-Ray Absorption by Ointment Containing Bismuth Oxide Nanoparticles in Radiology Staff

Introduction: The effects of X-rays on carcinogens have been proven in recent years. Today, lead is used in many devices such as lead covers, thyroid protectors to protect the body against x-rays. But this equipment contains many disadvantages such as, Toxicity, High weight and Lack of flexibility. Today, newer methods, such as semi-solid skin care products (cream, ointment), a...

متن کامل

In situ X-ray probing reveals fingerprints of surface platinum oxide.

In situ X-ray absorption spectroscopy (XAS) at the Pt L(3) edge is a useful probe for Pt-O interactions at polymer electrolyte membrane fuel cell (PEMFC) cathodes. We show that XAS using the high energy resolution fluorescence detection (HERFD) mode, applied to a well-defined monolayer Pt/Rh(111) sample where the bulk penetrating hard X-rays probe only surface Pt atoms, provides a unique sensit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 85 8  شماره 

صفحات  -

تاریخ انتشار 2014