Magnetization transfer effects in MR-detected multiple sclerosis lesions: comparison with gadolinium-enhanced spin-echo images and nonenhanced T1-weighted images.
نویسندگان
چکیده
PURPOSE To define the relationship between magnetization transfer and blood-brain-barrier breakdown in multiple sclerosis lesions using gadolinium enhancement as an index of the latter. METHODS Two hundred twenty lesions (high-signal abnormalities on T2-weighted images) in 35 multiple sclerosis patients were studied with gadolinium-enhanced spin-echo imaging and magnetization transfer. Lesions were divided into groups having nodular or uniform enhancement, ring enhancement, or no enhancement after gadolinium administration. For 133 lesions, T1-weighted images without contrast enhancement were also analyzed. These lesions were categorized as isointense or hypointense based on their appearance on the unenhanced T1-weighted images. RESULTS There was no difference between the magnetization transfer ratio (MTR) of lesions as a function of enhancement. MTR of hypointense lesions on unenhanced T1-weighted images was, however, lower than the MTR of isointense lesions. CONCLUSION We speculate that diminished MTR may reflect diminished myelin content and that hypointensity on T1-weighted images corresponds to demyelination. Central regions of ring-enhancing lesions had a lower MTR than the periphery, suggesting that demyelination in multiple sclerosis lesions occurs centrifugally. In addition, the short-repetition-time pulse sequence seems useful in the evaluation of myelin loss in patients with multiple sclerosis.
منابع مشابه
Enhanced and unenhanced MR with magnetization transfer in multiple sclerosis.
PURPOSE To evaluate the use of magnetization transfer and the apparent enhancement of lesions on contrast-enhanced MR images in patients with multiple sclerosis. METHODS Contrast-enhanced T1-weighted spin-echo MR images obtained in 20 patients with relapsing-remitting multiple sclerosis, with and without magnetization transfer, were evaluated to determine the number of enhancing plaques. Comp...
متن کاملSingle-dose gadolinium with magnetization transfer versus triple-dose gadolinium in the MR detection of multiple sclerosis lesions.
PURPOSE To compare the efficacy of single-dose gadolinium with magnetization transfer contrast (MTC) with that of triple-dose gadolinium in detecting enhancing multiple sclerosis lesions. METHODS Twenty-one patients with multiple sclerosis were examined with MR imaging first with 0.1 mmol/kg gadolinium (single dose) and then, after 24 to 72 hours, with 0.3 mmol/kg gadolinium (triple dose). T2...
متن کاملCranial tissues: appearance at gadolinium-enhanced and nonenhanced MR imaging with magnetization transfer contrast.
PURPOSE To determine the relative contrast of normal cranial tissues at magnetization transfer (MT) spin-echo magnetic resonance (MR) imaging. MATERIALS AND METHODS MR imaging at 1.5 T was performed with conventional spin-echo techniques without and with off-resonance MT saturation pulses. The signal intensities of normal cranial tissues were measured in 10 healthy volunteers on spin-density-...
متن کاملA comparison of MR sequences for lesions of the parotid gland.
PURPOSE To compare six MR sequences (plain and gadolinium-enhanced fat suppressed T1-weighted spin echo, T2-weighted standard spin echo, fat-suppressed and non-fat-suppressed T2-weighted fast spin echo, and inversion-recovery T2-weighted fast spin echo) in their ability to detect, delineate, and characterize lesions of the parotid gland. METHODS Fifty-eight parotid gland lesions imaged on 47 ...
متن کاملT1-weighted three-dimensional magnetization transfer MR of the brain: improved lesion contrast enhancement.
PURPOSE We developed and evaluated clinically T1-weighted three-dimensional gradient-echo magnetization transfer (MT) sequences for contrast-enhanced MR imaging of the brain. METHODS A short-repetition-time, radio frequency-spoiled, 3-D sequence was developed with a 10-millisecond MT pulse at high MT power and narrow MT pulse-frequency offset, and the enhancing lesion-to-normal white matter b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 16 1 شماره
صفحات -
تاریخ انتشار 1995