Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium: impact of ablation site, electrode size, and convective cooling.

نویسندگان

  • H Høgh Petersen
  • X Chen
  • A Pietersen
  • J H Svendsen
  • S Haunsø
چکیده

BACKGROUND It is important to increase lesion size to improve the success rate for radiofrequency ablation of ischemic ventricular tachycardia. This study of radiofrequency ablation, with adjustment of power to approach a preset target temperature, ie, temperature-controlled ablation, explores the effect of catheter-tip length, ablation site, and convective cooling on lesion dimensions. METHODS AND RESULTS In vitro strips of porcine left ventricular myocardium during different levels of convective cooling and in vivo pig hearts at 2 or 3 left ventricular sites were ablated with 2- to 12-mm-tip catheters. We found increased lesion volume for increased catheter-tip length </=8 mm in vitro (P<0.05) and 6 mm in vivo (P<0. 0001), but no further increase was found for longer tips. For the 4- to 10-mm catheter tips, we found smaller lesion volume in low-flow areas (apex) than in high-flow areas (free wall and septum) (P<0.05). Increasing convective cooling of the catheter tip in vitro increased lesion volume (P<0.0005) for the 4- and 8-mm tips but not for the 12-mm tip as the generator reached maximum output. In contrast to power-controlled ablation, we found a negative correlation between tip temperature reached and lesion volume for applications in which maximum generator output was not achieved (P<0. 0001), whereas delivered power and lesion volume correlated positively (P<0.0001). CONCLUSIONS Lesion size differs in different left ventricular target sites, which is probably related to convective cooling, as illustrated in vitro. Longer electrode tips increase lesion size for tip lengths </=6 to 8 mm. For temperature-controlled ablation, the tip temperature achieved is a poor predictor of lesion size.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Convective cooling effect on cooled-tip catheter compared to large-tip catheter radiofrequency ablation.

BACKGROUND Both actively cooled-tip and large-tip catheters are currently available clinically to create large endomyocardial lesions during application of radiofrequency (RF) energy. The purpose of this study was to compare the effect of convective cooling at physiologic flow rates on RF lesion size using both actively cooled and large-tip catheters. METHODS Porcine hearts were sectioned int...

متن کامل

Catheter Ablation of Accessory Pathways

Background. Animal studies have suggested that the temperature of the electrode-tissue interface during radiofrequency catheter ablation accurately predicts lesion size. The purpose of the current study was to evaluate the utility of continuous temperature monitoring during radiofrequency catheter ablation in patients with Wolff-Parkinson-White syndrome. Methods and Results. Twenty patients wit...

متن کامل

Microwave catheter ablation of myocardium in vitro. Assessment of the characteristics of tissue heating and injury.

BACKGROUND Radiofrequency (RF) catheter ablation lesion size has been limited by the small volume of tissue directly heated by the RF electrode. Microwave (MW) energy has been proposed as an alternative energy source to generate larger lesions because of its increased volume of direct tissue heating. To further characterize MW ablation of myocardium, we studied the temperature-versus-distance p...

متن کامل

LESION SIZE ESTIMATOR FOR CARDIAC RADIOFREQUENCY ABLATION by YU-CHI LAI UNIVERSITY OF WISCONSIN-MADISON DEPT. OF ELECTRICAL AND COMPUTER ENGINEERING

This work outlines a process for finite element (FE) modeling implementations of temperaturecontrolled radiofrequency (RF) ablation (TCRFA) with an automated temperature controller to investigate effects of changes in control temperature and contact conditions on the formation of lesions. The conditions investigated include ablation location, dimension of the myocardium, blood–electrode and blo...

متن کامل

Temperature monitoring during radiofrequency catheter ablation of accessory pathways.

BACKGROUND Animal studies have suggested that the temperature of the electrode-tissue interface during radiofrequency catheter ablation accurately predicts lesion size. The purpose of the current study was to evaluate the utility of continuous temperature monitoring during radiofrequency catheter ablation in patients with Wolff-Parkinson-White syndrome. METHODS AND RESULTS Twenty patients wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 99 2  شماره 

صفحات  -

تاریخ انتشار 1999