Scald risk in social housing can be reduced through thermostatic control system without increasing Legionella risk: a cluster randomised trial.

نویسندگان

  • P Edwards
  • M A Durand
  • M Hollister
  • J Green
  • S Lutchmun
  • A Kessel
  • I Roberts
چکیده

OBJECTIVE To quantify the effects of a thermostatic control system in social (public) housing on the prevalence of dangerous (>60°C) water temperatures and on fuel consumption. DESIGN Pair-matched double-blind cluster randomised controlled trial. SETTING Social housing in a deprived inner-London borough. PARTICIPANTS 150 households recruited as clusters from 22 social housing estates. Four small estates were combined into two clusters (resulting in a total of 10 pairs of clusters). INTERVENTION Social housing estate boiler houses were randomised to a thermostatic control sterilisation programme (heating water to 65°C during 00:00-06:00 h and to 50°C from 06:00 to 00:00 h daily) or to standard control (constant temperature 65°C). MAIN OUTCOME MEASURES Water temperature over 60°C ('dangerous') after running taps for 1 min and daily fuel consumption (cubic feet of gas). RESULTS 10 clusters (80 households) were allocated to the sterilisation programme and 10 clusters (70 households) to control, of which 73 and 67 households, respectively, were analysed. Prevalence of dangerous (>60°C) hot water temperatures at 1 min was significantly reduced with the sterilisation programme (mean of cluster prevalence 1% in sterilisation programme group vs 34% in control group; absolute difference 33%, 95% CI 12% to 54%; p=0.006). Prevalence of high (>55°C) hot water temperatures at 1 min was significantly reduced (31% sterilisation vs 59% control; absolute difference 28%, 95% CI 9% to 47%; p=0.009). Gas consumption per day reduced more in the control group than in the sterilisation programme group, although not statistically significantly (p=0.125). CONCLUSIONS The thermostatic control with daily sterilisation was effective in capping hot water temperatures and therefore reduced scald risk. Although expected to save energy, fuel consumption was increased relative to the control group. Trial registration ClinicalTrials.gov ID: NCT00874692.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preventing bath water scalds: a cost-effectiveness analysis of introducing bath thermostatic mixer valves in social housing.

AIMS To assess the cost-effectiveness of installing thermostatic mixer valves (TMVs) in reducing risks of bath water scalds and estimate the costs of avoiding bath water scalds. METHODS The evaluation was undertaken from the perspective of the UK public sector, and conducted in conjunction with a randomised control trial of TMVs installed in social housing in Glasgow. Installation costs were ...

متن کامل

Randomised controlled trial of thermostatic mixer valves in reducing bath hot tap water temperature in families with young children in social housing: A protocol

BACKGROUND Each year in the UK 2000 children attend emergency departments and 500 are admitted to hospital following a bath water scald. The long term effects can include disability, disfigurement or psychological harm and repeated skin grafts may be required as the child grows. The costs of treating a severe scald are estimated at 250,000 GBP. Children living in the most deprived wards are at ...

متن کامل

Intermittent use of copper-silver ionization for Legionella control in water distribution systems: a potential option in buildings housing individuals at low risk of infection.

One copper-silver ionization system was sequentially installed onto the hot-water recirculation lines of two hospital buildings colonized with Legionella pneumophila, serogroup 1. A third building with the same water supply and also colonized with Legionella served as a control. Four weeks after activation of the system, distal site positivity for Legionella in the first test building dropped t...

متن کامل

Randomised controlled trial of thermostatic mixer valves in reducing bath hot tap water temperature in families with young children in social housing.

OBJECTIVES To assess the effectiveness of thermostatic mixing valves (TMVs) in reducing bath hot tap water temperature, assess acceptability of TMVs to families and impact on bath time safety practices. DESIGN Pragmatic parallel arm randomised controlled trial. SETTING A social housing organisation in Glasgow, Scotland, UK. PARTICIPANTS 124 families with at least one child under 5 years. ...

متن کامل

Increasing young adults’ condom use intentions and behaviour through changing chlamydia risk and coping appraisals: study protocol for a cluster randomised controlled trial of efficacy

BACKGROUND Chlamydia is the most commonly diagnosed sexually transmitted infection (STI) in England and has serious public health consequences. Young people carry a disproportionate burden of infection. A number of social cognition models identify risk appraisal as a primary motivator of behaviour suggesting that changing risk appraisals for STIs may be an effective strategy in motivating prote...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood

دوره 96 12  شماره 

صفحات  -

تاریخ انتشار 2011