Shaping ability of ProTaper Universal, WaveOne and ProTaper Next in simulated L-shaped and S-shaped root canals

نویسندگان

  • Hui Wu
  • Cheng Peng
  • Yulong Bai
  • Xin Hu
  • Lei Wang
  • Changyi Li
چکیده

BACKGROUND The purpose of this study was to compare the shaping ability of the ProTaper Universal (PTU; Dentsply Maillefer, Ballaigues, Switzerland), WaveOne (WO; Dentsply Maillefer) and ProTaper Next (PTN; Dentsply Maillefer) in simulated L-shaped and S-shaped root canals respectively. METHODS 30 simulated L-shaped and 30 simulated S-shaped root canals in resin blocks were employed and randomly divided into 3 groups (n = 10), respectively. The canals were prepared to a tip size 25 using PTU, WO or PTN: PTU F2 (taper 0.08 over the first 3 mm from apical tip), WO Primary (taper 0.08 over the first 3 mm from apical tip), and PTN X2 (taper 0.06 over the first 3 mm from apical tip). Photos of the simulated root canals were taken pre- and postinstrumentation. The 2 layers were superimposed after a series of image processing and 10 points were selected from apical constriction with 1 mm interval. And then the central axis transportation and straightened curvature were measured with software of image analysis. RESULTS In simulated L-shaped root canals, PTU and PTN caused less transportation than WO at curved section (P < 0.05), and PTN caused the least transportation at apical constriction (P < 0.05). Moreover, PTN maintained the canal curvature best among the 3 groups (P < 0.05). But PTN produced more transportation at straight section compared with PTU and WO (P < 0.05). In simulated S-shaped root canals, PTN preserved the coronal curvature best (P < 0.05), but there was no significant difference in apical curvature since all the files straightened the curvature obviously. CONCLUSIONS PTN showed a better shaping ability than PTU and WO at the curved section of root canals, and PTN maintained the best apical constriction. But all the files had a tendency to straighten the apical curvature in multi-curved canals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Operator's Experience on the Shaping Ability of Protaper Universal and Waveone Systems: A Comparative Study on Simulated Root Canals

OBJECTIVE To assess the influence of operator experience on: shaping and centering ability, mean preparation time and presence of canal aberrations of ProTaper Universal and WaveOne systems on simulated root canals. MATERIALS AND METHODS Sixty S-shaped canals in resin blocks were assigned to four groups (n=15 for each group). Group1 (Experienced operator, ProTaper), Group2 (Experienced operat...

متن کامل

Centering Ability of ProTaper Next and WaveOne Classic in J-Shape Simulated Root Canals

Introduction. The aim of this study was to evaluate and compare the shaping and centering ability of ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland) and WaveOne Classic systems (Dentsply Maillefer) in simulated root canals. Methods. Forty J-shaped canals in resin blocks were assigned to two groups (n = 20 for each group). Photographic method was used to record pre- and postinst...

متن کامل

Comparison of WaveOne and ProTaper Universal Preparation Systems in the Amount of Smear Layer/Debris Production: an in-vitro SEM Study

Background and Aim: Debris and the smear layer that remain after root canal preparations may result in failure of root canal therapies. The aim of this study was to compare the smear layer formation and the amount of residual debris following the use of WaveOne and ProTaper rotary files in mesiobuccal root canals of upper first molars by scanning electron microscopy (SEM). Materials and Method...

متن کامل

Root canal preparation of mandibular molars with 3 nickel-titanium rotary instruments: a micro-computed tomographic study.

INTRODUCTION The aim of this study was to describe the canal shaping properties of ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Universal (PTU; Dentsply Tulsa Dental Specialties, Johnson City, TN), and WaveOne (Dentsply Maillefer) nickel-titanium instruments in mandibular first molars by using micro-computed tomographic (micro-CT) scanning. METHODS A total of 36 ...

متن کامل

Shaping ability of two M-wire and two traditional nickel-titanium instrumentation systems in S-shaped resin canals.

AIMS The aim of this study was to evaluate the shaping effects of two M-wire and two traditional nickel-titanium (NiTi) rotary systems in simulated S-shaped resin canals. SUBJECTS AND METHODS Forty simulated S-shaped canals in resin blocks were instrumented with two traditional (ProTaper, Sendoline S5) and two M-wire (WaveOne, GT series X) NiTi systems according to the manufacturers' instruct...