Hyper-Rayleigh spectral intensities of gaseous Kr-Xe mixture.

نویسندگان

  • W Głaz
  • T Bancewicz
  • J L Godet
چکیده

Binary collision-induced hyper-Rayleigh (CIHR) spectra of Kr-Xe gaseous system are computed quantum mechanically and classically within the frequency range up to 380 cm(-1). The intensities are expressed in absolute units. The details of the theory developed for the CIHR spectra are given and the properties of the profiles as well as the depolarization ratio frequency dependence are discussed. The contributions to the spectra related to the vector b10(r) and the septor b30(r) components of the hyperpolarizability tensor are evaluated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of low-xenon and krypton supplementation on signal/noise of regional CT-based ventilation measurements.

Xenon computed tomography (Xe-CT) is used to estimate regional ventilation by measuring regional attenuation changes over multiple breaths while rebreathing a constant Xe concentration ([Xe]). Xe-CT has potential human applications, although anesthetic properties limit [Xe] to <or=35%. We investigate effects of lower [Xe], including a low [Xe]-krypton (Kr) combination, on time constant (TC) det...

متن کامل

Wideband Tuning of the Blue-Green XeF(C-->A) Laser

Efficient wavelength tuning from 446 to 524nm with a minimum spectral linewidth of lnm was demonstrated for an electron beam pumped XeF(C~A) laser. Energy densities of 0.1 J/1 were obtained for an optimized Ar/Kr/Xe/Fz/NFa mixture.

متن کامل

Spectral measurements of hyper-Rayleigh light scattering

An apparatus is described for the measurement of second-order nonlinear optical properties via hyper-Rayleigh scattering with 1 cm spectral resolution of the scattered light. The setup allows a complete investigation of the polarization dependence of the second-harmonic scattered light. The combination of good spectral resolution, polarization analysis, and high sensitivity allows the determina...

متن کامل

Estimation of second virial coefficients for rare gases in thermodynamic views

Using the Gaussian 2003 software and MP2/ 6–311 ++ G** method for He: He, Ne:Ne andMP2/6-31G method for Ar: Ar, Kr: Kr and HF/STO-3G method for Xe: Xe, the optimizedinteraction energies between two like atoms of rare gases (He, Ne, Ar, Kr and Xe) as a functionof the distances between the centers of two considered atoms were evaluated and the resultswere interpreted according to the Lennard – Jo...

متن کامل

Regional ventilation studies with Kr-81m and Xe-133: a comparative analysis.

Krypton-81m and Xe-133 ventilation scintigrams, and particulate per fusion scintigrams with Tc-99m, were obtained on the same day in 41 pa tients. Of 14 studies demonstrating pulmonary embolism, Kr-81m corn plernented the perfusion study better than Xe-133 in seven and was judged essential for that diagnosis in two. Xenon-133 was better in none. On the other hand, in 29 studies with obstructive...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of chemical physics

دوره 122 22  شماره 

صفحات  -

تاریخ انتشار 2005